KYORITSU 1051 Digital Multimeter (True RMS)

DCV: 600.0mV/6.000/60.00/600.0/1000V

ACV[RMS]: 600.0mV/6.000/60.00/600.0/1000V

DCA: 600.0/6000μA/60.00/440.0mA/6.000/10.00A

ACA [RMS]: 600.0/6000μA/60.00/440.0mA/6.000/10.00A

Ω: 600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ

Continuously monitored: 600.0Ω

Checkdiode: 2V

C: 10.00/100.0nF/1.000/10.00/100.0/1000μF

F: 10.00~~9.999/9.00999.9Hz/0.90099.99/90.0~~99.99kHz

Temperature: -50~ 600ºC(withK-typeTemperatureprobe)

Other Features: DataHold (D/H),AutoHold(A /H), RangeHold (R/H)...

Source: R6P(1.5V)× 4

Size: 192 (L)×90 (W)×49 (D)mm

Weight: 560g

Accessories: Battery,probe,Manuals

Details
High Accuracy, High Performance and Reliable Measurements
0.09% basic DC accuracy
Large display with 6,000 counts
True-RMS Measurements
True-RMS or MEAN value detection mode can be selected *
Low-pass filter for motor drive measurements
User calibration function
Safety design for industrial use
Complies with IEC 61010-1 CAT.IV 600V,
CAT.III 1000V
Terminal shutter to prevent incorrect insertion of test leads in current terminals
Very wide operating temperature range from
-10 to 55ºC

1051/1052
CE
(Photo: 1052)
Reliable support for data management *
Large data internal memory *
  KEW 1052: 1,600 data (logging), 100 data (manual)
Download data and Live Monitoring on a PC via the USB interface
(Option for USB Communication set) *
* Only for KEW 1052

NEW TRUE RMS CAT.IV 600V
KEW 1051 KEW 1052
Detection mode RMS MEAN/RMS (switch)
DC V 600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ [600mV/60/600/1000V], 11MΩ [6V])

|±0.09%rdg±2dgt (Basic accuracy)
AC V [RMS] 600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ<200pf 600mv="" 11m="" 50pf="" 6v="" br=""> 10MΩ<50pf 60="" 600="" 1000v="" span="">

|±0.5%rdg±5dgt (Basic accuracy)
DC A 600.0/6000µA/60.00/440.0mA/6.000/10.00A

|±0.2%rdg±2dgt (Basic accuracy)
AC A [RMS] 600.0/6000µA/60.00/440.0mA/6.000/10.00A

|±0.75%rdg±5dgt (Basic accuracy)
Ω 600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ

|±0.4%rdg±1dgt (Basic accuracy)
Continuity buzzer 600.0Ω (The buzzer turns on for resistances lower than 50±30Ω)
Diode test 2.000V|±1%rdg±2dgt
Open curcuit voltage: <3.5v approx="" 0="" 5ma="" measuring="" current="" td="">
Capacitance 10.00/100.0nF/1.000/10.00/100.0/1000µF

|±2%rdg±5dgt (Basic accuracy)
Frequency 10.00~99.99/90.0~999.9Hz/0.900~9.999/9.00~99.99kHz

|±0.02%rdg±1dgt (Basic accuracy)
Temperature -50~600ºC|±2%rdg±2ºC (with the use of K-type Temperature probe)
Other functions Data Hold (D/H), Auto Hold (A/H), Range Hold (R/H),
Maximum value (MAX) *, Minimum value (MIN) *, Average value (AVG) *, Zero Adjustment (Capacitor, Resistance), Save to Memory *,
LCD backlight
Withstand voltage 6,880V/5 sec.
Applicable
standards
IEC 61010-1 CAT.IV 600V, CAT.III 1000V Pollution degree 2,
IEC 61010-031, IEC 61326-1 (EMC)