Measuring Range:

600.0mV/6.000/60.00/600.0V (Input impedance: approx. 10MΩ)

±1.0%rdg±3dgt

AC V: 6.000/60.00/600.0V (Input impedance: approx.10MΩ)

±1.5%rdg±5dgt (45 - 400Hz)

DC A: 

60.00/120.0A

±2.0%rdg±8dgt (60A)

±2.0%rdg±5dgt (120A)

AC A: 60.00/120.0A

±2.0%rdg±5dgt (45 - 65Hz)

Ω: 600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ

±1.0%rdg±5dgt (600Ω/6/60/600kΩ)

±2.0%rdg±5dgt (6MΩ)

±3.0%rdg±5dgt (60MΩ)

Continuity buzzer: Buzzer sounds below 35±25Ω

Diode test: 2.000V±3.0%rdg±5dgt Open-loop voltage: approx. 2.7V

Capacitance: 400.0nF/4.000/40.00µF

±2.5%rdg±10dgt

Frequency: 

(AC A) 99.99/400.0Hz ±0.2%rdg±2dgt (100Hz) ±0.1%rdg±1dgt (400Hz)

(AC V) 99.99/999.9Hz/9.999/99.99/300.0kHz ±0.2%rdg±2dgt (100Hz)

±0.1%rdg±1dgt (1000Hz/10/100/300.0kHz)

(Input sensitivity: 

Current: more than 6A

Voltage: more than 6V [- 10kHz]/more than 20V [10k - 300kHz])

Conductor size: Ø12mm max.

Applicable standards: IEC 61010-1 CAT III 300V, CAT II 600V Pollution degree 2

IEC 61010-031, IEC 61010-2-032, IEC 61326-1, EN 50581(RoHS)

Power source: R03 (AAA)(1.5V) × 2

* Continuous measuring time:

DCV: approx. 150hours, ACA: approx. 25hours

(Auto power save: approx. 15 minutes)

Dimensions: 128 (L) × 92 (W) × 27 (D) mm

Weight: 220g approx. (including batteries)

Included Accessories: R03 (AAA) × 2, Instruction manual

Optional Accessories: 9107 (Carrying case [Soft])