For full functionality of this site it is necessary to enable JavaScript.

NGI N6906-1000-60 Single-Channel High Power DC Electronic Load (6kW, 1000V, 60A)

Voltage: 1000V

Current: 60A

Power: 6000W

Min operating voltage: 5@6A/ 5V@60A

CC mode

Range: 0~6A/ 0~60A

Setting Resolution: 0.1mA/ 1mA

Setting Accuracy (23±5℃): 0.05%+0.05%F.S.

CV mode

Range: 0~100V/ 0~1000V

Setting Resolution: 10mV/ 100mV

Setting Accuracy: (23±5℃) 0.05%+0.05%F.S.

CP mode

Range: 0~6000W

Setting Resolution: 0.1W

Setting Accuracy (23±5℃): 0.5%+0.5%F.S

CR mode

Range: 0.31Ω~1666Ω / 6.2Ω~16666Ω

Setting Resolution: 16 bits

Setting Accuracy (23±5℃): 0.35%+1.9mS / 0.35%+0.19mS

Slew Rate

Current: 1~60A/ms /60~3000A/ms

Voltage: 8-400V/ms / 400-4000V/ms

Power: 1~60A/ms /60~3000A/ms

Resistance: 1~60A/ms /60~3000A/ms

Voltage Measurement

Range: 0~100V/ 0~1000V

Readback Accuracy (23±5℃): 0.05%+0.05%F.S.

Current Measurement

Range: 0~6A / 0~60A

Readback Accuracy (23±5℃):0.05%+0.05%F.S.

Power Measurement

Range: 0~6000W

Readback Accuracy (23±5℃): 0.5%+0.5%F.S. 

Interface: LAN/RS232/CAN

AC Input: Single phase, 220V AC±10%, frequency 47Hz~63Hz

Sampling Frequency: 25Hz

Communication Response Time: ≤10ms

Operating Environment: Altitude: <2000m, relative humidity: 5%~90%RH(non-condensing), atmospheric pressure: 80~110kPa

Temperature: Operating temperature: 0℃~40℃, storage temperature: -20℃~60℃

Net weight: Approx. 54kg

Dimension: 6U, 265.0(H)*482.0(W)with handle*612.0(D)mm

Details

Datasheet

  • Quality Engagement
  • Easy change and return
  • Delivery Avaliable
  • Favorable payment

Apply your mail to get promotion information