Measurement values: Measurement ranges / resolution / accuracy

PCE-830 + PCE-6801

Watts AC (50 Hz or 60 Hz, PF 0.5 up to 1): 5.0 W to 999.9 W / 0.1 W / ±1% ±0.8 W

1.000 kW to 9.999 kW / 0.001 k W / ±1% ±8 W

10.00 kW to 99.99 kW / 0.01 kW / ±1% ±80 W

100.0 kW to 999.9 kW / 0.1 kW / ±1% ±0.8 kW

1000 kW to 9999 kW / 1 kW / ±1% ±8 kW

PCE-830 + PCE-6801

Current AC (50 Hz or 60 Hz, auto range select, TRMS): 0.04 A to 1 A / 0.001 A / ±0.5% ±0.05 A

0.4 A to 10.0 A / 0.01 A / ±0.5% ±0.05 A

4 A to 100.0 A / 0.1 A / ±1.0% ±0.5 A

Voltage AC (50 Hz or 60 Hz, TRMS): 20.0 V to 500.0 V / 0.1 V / ±0.5% ±5 digits

(measure between phase and neutral)

20.0 V to 600.0 V / 0.1 V / ±0.5% ±5 digits

(measure between phase and neutral)

Harmonic distortion of AC voltage: 1º to 20º / 0.1% / ±1.0%

21º to 49º / 0.1% / 4% of reading ±2.0%

50º to 99º / 0.1% / 6% of reading ±2.0%

PCE-830 + PCE-6801

Harmonics of AC current in %: 1º to 20º / 0.1% / ±0.2% of reading ±1.0%

11º to 20º / 0.1% / ±2% of reading ±1.0%

21º to 50º (A)/ 0.1% / ±5% of reading ±1.0%

21º to 50º (mA)/ 0.1% / ±10% of reading ±1.0%

51º to 99º / 0.1% / ±35% of reading ±1.0%

PCE-830 + PCE-6801 

Power Factor (PF): 0.00 to 1.00 / 0.01 / ±0.04

PCE-830 + PCE-6801

Phase angle (Phi): -180° to 180° / 0.1° / ±1°

PCE-830 + PCE-6801

Total harmonic distortion: 0.0 to 20.0% / 0.1% / ±1%

20.0% to 100% / 0.1% / ±3% of reading ±5%

100% to 999.9% / 0.1% / ±10% of reading ±10%

Maximum measurement of AC voltage and current: 50 Hz / 19 µS / ±5% ±30 digits

60 Hz / 16 µS / ±5% ±30 digits

Peak value measurementof AC voltage and current: 1.00 to 99.99 / 0.01 / ±5% ±30 digits

Frequency range in automatic mode: 45 Hz to 65 Hz / 0.1 Hz / 0.1 Hz

Memory: 512 kB for a maximum 52,420 readings taken by 1 phase / 2 conductors

Port: USB

Software and cable: Included, for Windows 2000, XP, ME

Display: Backlit LCD with dot matrix

Power: 8 AA batteries (Mignon)

Dimensions: 257 mm x 155 mm x 57 mm

10.1 in x 6.1 in x 2.2 in

Weight: 1.16 kg / 2.56 lbs

Operating conditions: Max. 85% relative humidity / -10 ... 50ºC / 14 ... 122°F

Type of protection / standards: IEC 61010, 600 V/CAT III


Dilivery Contents

1 x PCE-830 3-Phase-Power Meter

3 x Amp clamps - PCE-6801

4 x Alligator clips 

4 x Safety test lines (3 m / 3.3 ft long),

8 x Batteries 

1 x Mains adaptor

1 x Carrying case 

1 x USB cable software

1 x User's manual