PINTEK PS-1000 Analog Oscilloscope (100MHz, 2CH)
Manufacturer: PINTEK Model: PS-1000 Origin: Taiwan - Contact
See more: Equipment Calibration-Inspection & Repair Service
Call for the best price
Hanoi city: (024) 35.381.269
Danang city: (023) 63.747.711
Bac Ninh city: (0222) 730.39.68
Hai Phong city: (0225) 730.03.89
HCM city: (028) 38.119.636
Dong Nai: 0932.160.940
100MHz BANDWIDTH.
20MHz LIMIT.
1mV SENSITIVITY.
2.0nS RESOLUTION.
CE. TUV GS, UL, CUL, IEC1010
CRT
| Type : | Rectangular with integral graticule. |
| Display Area : | 8 x 10 div ( 1 div = 1 cm ) |
| Accelerating Voltage : | 14 kV. |
| Phosphor : | P31. |
|
VERTICAL AMPLIFIERS ( CH 1 and CH 2 ) |
|
| Sensitivity : |
5 mV / div to 5 V / div ( X1 mode ). |
| Accuracy : | ± 3 % ( X1 mode ). ± 5 % ( X5 mode ). |
| Input Resistance: | 1 MΩ ± 2 % |
| Input Capacitance: | 25 pF ± 10 pF. |
|
Frequency Response: |
|
| 5 mV to 5 V / div ( CAL ): | DC to 25 MHz (-3 dB). |
| 1 mV / div (CAL): | 5mV/div~5V/div: DC~50MHz(-3db) |
| Rise Time: | Approximately 3.5 ns. |
| Operaing Modes: | |
| CH1: | CH 1, single trace. | |
| CH2: | CH 2, single trace. | |
| ALT: | Dual trace, alternating. | |
| CHOP: | dual trace, chopped. | |
| ADD: | algebraic sum of CH 1 + CH 2. | |
| Polarity Reversal (Invert): | CH 2 only. | |
| Maximum Input Voltae: | 400 V dc + ac peak. | |
|
Maximum Undistorted Amplitude: |
||
| DC-to-120 MHz: | 4 divisions. | |
| DC-to-60 MHz: | 8 divisions. | |
|
HORIZONTAL AMPLIFIER ( Input through channel 1 input ) |
||
| X-Y mode: | switch selectable using X-Y switch. | |
| CH 1: | X axis. | |
| CH 2: | Y axis. | |
| Sensitivity: | 1mV/DIV - 5V/DIV | |
|
Accuracy: |
||
| Y-Axis: | ± 3%. | |
| X-Axis: | ± 6%. | |
| Input Impedance: |
1MΩ //25PF |
|
| Frequency Response: | DC to 1 MHz typical ( -3 dB ). | |
| X-Y Phase Difference: | Approximately 3° at 50 kHz. | |
| Maximum Input Voltage: | 400V dc+ac pack | |
|
SWEEP SYSTEM |
||
| Sweep Speed: | 20 ns/div to 0.5 s/div in 1-2-5 sequence, 23 steps.Vernier control porvides fully adjustable sweep time between steps. |
|
| Accuracy: | ± 3 %. | |
| Sweep Magnification: | 10X, ± 10% extend sweep speed up tp 2 ns/div. |
|
| Holdoff: | Continuously adjustable from NORM to 5 times normal. | |
|
TRIGGERING |
||
| Trigger Modes: | AUTO ( free run ) or NORM. | |
| Trigger Source: | CH1, CH2, ALT, EXT, LINE. | |
|
Maximum External Trigger Voltage: |
300 V dc + ac peak. | |
|
Trigger Coupling: |
||
| AUTO ( AC ): | 30 Hz to 120 MHz. | |
| TV-H ( AC ): | Used for triggering from horizontal sync pulses. | |
| TV-V ( DC ): | Used for triggering from vertical sync pulses. | |
| Trigger Sensitivity: | ||
| Internal: | 1.0 division. | |
| External: | 200 mV. | |
|
OTHER SPECIFICATIONS |
||
| Calibrating Voltage: | 1 kHz ( nominal ) Positive Square Wave, 0.5 V p-p ( ± 3% ) | |
| Trace Rotage: | Electrical, front panel adjustable. | |
| Power Requirements: | 115/230 VAC ± 10%, 50/60Hz,? approximately 60 W. |
|
| Dimensions: | 324 x 132 x 398 mm ( 12.8 x 5.2 x 15.6" ). | |
| Weight: | Approximately 8.5 kg ( 18.7 1bs ). | |
| C E STANDARD: | E.M.C. Regulations-1992 )E.C. Directive 89/336/EEC)EN 50081-1 Emissions. EN 50082-1 Immunity. |
|