For full functionality of this site it is necessary to enable JavaScript.

Pintek PS-1005 Analog Oscilloscope ( 100MHz With Delay Sweep )

100MHz ALT TRIGGER.  
 20MHz LIMIT.  
 1mV/DIV SENSITIVITY.  
 2nS/DIV RESOLUTION.  
 DELAY SWEEP  
 CE, TUV GS, UL, CUL, IEC1010

Details

 

CATHODE RAY TUBE Accuracy
6 inch diagonal, rectangular screen with internal graticule
8 x 10 DIV
( 1 DIV = 1 cm ), P31 phosphor. 14 kV accel voltage.
+ / - 3%.
Sweep Magnification
VERTICAL DEFLECTION 10X, +/- 10% extend sweep speed up to 2nS/DIV.
Bandwidth Delay Time Position
DC-100 MHz ( -3db ) Variable control to locate desirable waveform for
extending.
Sensitivity TRIGGERING
1 mV / DIV - 1 V / DIV ( 25 MHz -3db ). x 5 gain selected.
5 mV / DIV - 5 V / DIV
Trigger Coupling
Attenuator AC,TV-V(DC), TV-H, LINE.
1-2-5 sequence. 10 step with variable control. Trigger Source
Input Impedance CH 1, CH2, ALT, LINE, EXT.
1MΩ ± 2% // 25 pF± 10 pF Slope
Max. Input Voltage + / -
400 V ( DC + AC peak ). TRIGGER SENSITIVITY
Rise Time
5mV/DIV - 5V/DIV : 3.5 nS
1mV/DIV : 14 nS
Over Shoot
Less than + / - 5 %
Operation Mode
COUPLING BANDWIDTH(Hz) INT(DIV) EXT(V)
TV - V
TV - H
AUTO
NORM
DC - 1 kHz
1 k - 100 k
100 - 100 M
100 - 100 M
1.0
1.0
2.0
2.0
0.1
0.1
0.2
0.2
CH 1, CH 2, DUAL (ALT, CHOP)
Algebraic Addition
CH 2 OUTPUT
Ouptut level
CH 1 + CH 2, CH 1 - CH 2
Inverter
CH 2 only.
100 mV/DIV (no load).
50 mV/DIV (with 50
Ω load).
Bandwidth
HOIZONTAL DEFLECTION 20 Hz-20 MHz ( -3 db ).
X-Y Mode switch selectable using X-Y switch Calibrator
CH 1 : X axis. Square wave 1 KHz ± 10 %, 0.5 Vp-p ± 3 %
CH 2 : Y axis. Z-Modulation
Accuracy
Y - Axis + / - 3 %
Positive TTL signal, low level blank intensity at any intensity, high level unblank any intensity.
X - Axis + / - 6 % Trace Rotation
Bandwidth Adjustable on front panel.
DC - 1 MHz ( -3db ). Power Source
X-Y Phase Difference 115, 230VAC ± 10%, 50/60 Hz.
Approximately 3° at 50 kHz. Power Consumption
SWEEP SYSTEM Apporx. 60 Watts.
Sweep Display Mode Dimensions
Main, Mix, Delay. 324 (W) x 398 (D) x 132 (H) mm.
Hold Off Time Net Weight
5:1 continuously variable. ( 0.1µS / DIV ) Approx. 8.5 kg.
MAIN SWEEP Rated Range of Use
Sweep Speed 10- 35, 10-80% R.H.
20 nS / DIV - 0.5S / DIV in 1-2-5 sequence 23 steps. Limits of Operation
Accuracy 0- 50, 10-80% R.H.
+ / -3 %. Storage Environment
Variable Time Control - 30- 70, 10-90% R.H.
5:1, uncalibrated, continuously variable between steps. C E STANDARD :
Sweep Magnification E.M.C. Regulations-1992 ( e.c. Directive 89/336/EEC )

10X, +/- 10% extend sweep speed up to 2 nS / DIV.

EN 50081-1 Emissions.
EN 50082-1 limmunity.
DELAY SWEEP  
Sweep Speed  
20 nS / DIV - 0.5S / DIV in 1-2-5 sequence 23 steps.  
  • Quality Engagement
  • Easy change and return
  • Delivery Avaliable
  • Favorable payment

Apply your mail to get promotion information