Rigel medical UNI-SiM Vital Signs Simulator (NIBP / SPO2 and ECG)
Manufacturer: Rigel medical Model: UNI-SiM P/N: 370A930 - Contact
See more: Equipment Calibration-Inspection & Repair Service
Call for the best price
Hanoi city: (024) 35.381.269
Danang city: (023) 63.747.711
Bac Ninh city: (0222) 730.39.68
Hai Phong city: (0225) 730.03.89
HCM city: (028) 38.119.636
Dong Nai: 0345.689.536
Non-invasive Blood Pressure
Simulation Waveform: Oscillometric.
Integrated Pump: 0 to 350 mmHg, user configurable.
Leak Test: User configurable between 0-350 mmHg.
Chronometer: Configurable up to 999 secs.
Digital Manometer: 0 - 410 mmHg.
Pressure Accuracy: ± 0.5% FS.
Pressure Units: mmHg, inHg, kg/cm², cmH₂O, mBar, PSI, inH₂O, and kPa.
ECG Arrhythmia Simulator
ECG: 5 lead simulation, including high-level output.
Wave Forms: Normal Sinus Rhythm (NSR), ST Elevation, ST Depression, Myocardial Infarction, Tall T.
Rate: 20 – 300 BPM, typed value.
Performance Waveforms: Sine, Square, Triangle, and Pulse.
Pacer Waveforms: Synchronous Atrial, Asynchronous Atrial.
Pacer Only: Pacer Pulse rate 60 BPM, Ventricular Pacer rate 70 BPM, Atrial & Ventricular Pacer Heart rate 70 BPM, R Wave Detection.
Temperature
Simulation: YSI 400 / 700 Static.
Range: Preset at 25, 33, 37, and 41°C.
Invasive Blood Pressure
Channels: 2 channels.
Static: 0 to 300 mmHg, typed values.
Dynamic: 0 - 300 mmHg for systolic & diastolic.
Oxygen Saturation
Range: 50 to 100%.
Accuracy: ± 1 bpm.
Chronometer: Test option to test response time of SpO₂ monitor.
Arrhythmia Waveforms
Atrial: Sinus Arrhythmia (SA), Missing Beat, Atrial Flutter (AFLT), Atrial Fibrillation (AFB), Paroxysmal Atrial Tachycardia (PAT), Junctional Premature Contraction.
Atrial Conduction: First Degree AV Block, Second Degree AV Block - Mobitz I, Second Degree AV Block - Mobitz II, Third Degree AV Block, Right Bundle Branch Block (RBB), Left Bundle Branch Block (LBB), Left Anterior Hemiblock.
Ventricular: Premature Ventricular Contraction - Intermittent, Premature Ventricular Contraction – Continuous, Bigeminy, Trigeminy, Ventricular Flutter (VFLT), Ventricular Fibrillation (VFB), Ventricular Tachycardia (VTC), Right Focal PVC.
Respiration
Rates: 5, 10, 15, 30, 60, 120, 180 Breaths per Minute.
Base Resistances: 250, 500, 750, 1000 ohms.
Apnoea Simulation: 0 – 60 seconds duration, 0 – 300 seconds interval.
General Specification
Operation: Battery cell, in-situ charge.
Battery Charger: 110-230VAC, 50/60 Hz.
Battery Life: 4-24 hours testing depending on simulations.
Memory Capacity: Approximately 10,000 records.
Communication: Via Bluetooth.
Display: Monochrome, ¼ VGA full graphics.
Keypad: Alpha-numeric.
Weight: <1.5 kg.
Size (L x W x D): 270 x 110 x 75 mm / 10.5 x 4 x 3”.
Operating Conditions: 10-30°C, 0-90% RH - NC.
Storage Environment: -15°C to +60°C.
Environmental Protection: IP 40.