Rigel medical UNI-SiM Vital Signs Simulator (NIBP / SPO2 and ECG)

Non-invasive Blood Pressure

Simulation Waveform: Oscillometric.

Integrated Pump: 0 to 350 mmHg, user configurable.

Leak Test: User configurable between 0-350 mmHg.

Chronometer: Configurable up to 999 secs.

Digital Manometer: 0 - 410 mmHg.

Pressure Accuracy: ± 0.5% FS.

Pressure Units: mmHg, inHg, kg/cm², cmH₂O, mBar, PSI, inH₂O, and kPa.


ECG Arrhythmia Simulator

ECG: 5 lead simulation, including high-level output.

Wave Forms: Normal Sinus Rhythm (NSR), ST Elevation, ST Depression, Myocardial Infarction, Tall T.

Rate: 20 – 300 BPM, typed value.

Performance Waveforms: Sine, Square, Triangle, and Pulse.

Pacer Waveforms: Synchronous Atrial, Asynchronous Atrial.

Pacer Only: Pacer Pulse rate 60 BPM, Ventricular Pacer rate 70 BPM, Atrial & Ventricular Pacer Heart rate 70 BPM, R Wave Detection.


Temperature

Simulation: YSI 400 / 700 Static.

Range: Preset at 25, 33, 37, and 41°C.


Invasive Blood Pressure

Channels: 2 channels.

Static: 0 to 300 mmHg, typed values.

Dynamic: 0 - 300 mmHg for systolic & diastolic.


Oxygen Saturation

Range: 50 to 100%.

Accuracy: ± 1 bpm.

Chronometer: Test option to test response time of SpO₂ monitor.


Arrhythmia Waveforms

Atrial: Sinus Arrhythmia (SA), Missing Beat, Atrial Flutter (AFLT), Atrial Fibrillation (AFB), Paroxysmal Atrial Tachycardia (PAT), Junctional Premature Contraction.

Atrial Conduction: First Degree AV Block, Second Degree AV Block - Mobitz I, Second Degree AV Block - Mobitz II, Third Degree AV Block, Right Bundle Branch Block (RBB), Left Bundle Branch Block (LBB), Left Anterior Hemiblock.

Ventricular: Premature Ventricular Contraction - Intermittent, Premature Ventricular Contraction – Continuous, Bigeminy, Trigeminy, Ventricular Flutter (VFLT), Ventricular Fibrillation (VFB), Ventricular Tachycardia (VTC), Right Focal PVC.


Respiration

Rates: 5, 10, 15, 30, 60, 120, 180 Breaths per Minute.

Base Resistances: 250, 500, 750, 1000 ohms.

Apnoea Simulation: 0 – 60 seconds duration, 0 – 300 seconds interval.


General Specification

Operation: Battery cell, in-situ charge.

Battery Charger: 110-230VAC, 50/60 Hz.

Battery Life: 4-24 hours testing depending on simulations.

Memory Capacity: Approximately 10,000 records.

Communication: Via Bluetooth.

Display: Monochrome, ¼ VGA full graphics.

Keypad: Alpha-numeric.

Weight: <1.5 kg.

Size (L x W x D): 270 x 110 x 75 mm / 10.5 x 4 x 3”.

Operating Conditions: 10-30°C, 0-90% RH - NC.

Storage Environment: -15°C to +60°C.

Environmental Protection: IP 40.