For full functionality of this site it is necessary to enable JavaScript.

Senseca LABO-HR2E-FPSD Flow transmitter (50...300l/min, frequency output)

Full scale value can be programmed (teaching possible)

Sensor: analog Hall sensor

Nominal width: DN 32 / 40 / 50

Process connection: female thread G 1 1/4..G 2 (further process connections available on request)

Metering range: 50....300 l/min for details see table "Ranges"

Pressure loss: ~ 1 bar at Qmax

Qmax.: up to 300 l/min

Measurement accuracy: 8% of full scale value

Pressure resistance: PS 200 bar

Medium temperature: -20..+85 °C, optionally -20..+120 °C

Ambient temperature: -20..+70 °C

Media: water

Wiring: see section "Wiring"

Materials medium-contact

Brass construction: CW614N nickelled, CW614N, 1.4305, 1.4310, hard ferrite,

Stainless steel construction: 1.4571, 1.4310, hard ferrite

Materials, non medium-contact: CW614N nickelled

Supply voltage: 18..30 V DC

Power consumption: < 1 W

Output: Frequency output

Transistor output "Push-Pull" (resistant to short circuits, and reversed polarity protected) lout = 100 mA max.

Selectable frequency, max. 2 kHz

Display: yellow LED (On = Normal / Off = Alarm / rapid flashing = Programming

Electrical connection: for round plug connector M12x1, 4-pole

Ingress protection: IP 67

Weight: see table "Dimensions and weights"

Conformity: CE

Installation location

Standard: horizontal inwards flow; other installation positions are possible; the installation position affects the display, metering and switching range.

Details

Datasheet

  • Quality Engagement
  • Easy change and return
  • Delivery Avaliable
  • Favorable payment

Apply your mail to get promotion information