For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0

The most correct way to measure an inductor with a multimeter

2024년 10월 22일 15시 08분 05초

Inductors are one of the important components in many modern electronic devices. When a problem occurs, it is necessary to check the inductor to evaluate its operating condition. A popular method chosen by many people is to measure the inductor with a multimeter. Measuring the inductor with DHVN helps determine whether the inductor is still working well or is damaged. So how does the inspection process work? Let's find out with EMIN in the article below!

Inductor concept

An inductor is a passive electronic component that creates a magnetic field when current flows through it. The structure of an inductor includes a coil of wire wound into many turns, allowing it to store energy in the form of a magnetic field. The unit of measurement for an inductor is self-inductance, also known as Henry, denoted H.

Introducing the method of using a multimeter to measure inductors

Measuring an inductor with a multimeter is a popular method due to its simplicity and accuracy. Multimeters equipped with the ability to measure inductors will have the symbol L (inductance) or the unit of measurement is H (Henry). Not all multimeters support this function, so you need to check the device carefully before using it.
Using a multimeter to measure inductors saves time and simplifies the testing process without the need for many other tools. This is a choice that many people trust when they need to quickly check and determine the parameters of the inductor.

Instructions for measuring inductors with a multimeter

Here are two popular methods you can apply:

Method 1: Measure the inductor using a voltage scale

Step 1: First, you adjust the needle to 0 on the voltage scale, then adjust the switch to the appropriate scale.
Step 2: Next, bring the switching head to the required voltage scale. Note that the scale you choose needs to be larger than the voltage you are expected to measure.
Step 3: Place two measuring sticks at two different points of the inductor. The red rod is placed in the higher voltage position, the black rod is in the lower position. For AC voltage measurement, you can place any stick on either terminal of the voltage. Then, record the value when the needle stops on the index line.
Step 4: To calculate the result, apply the formula: V = (A x B) / C, where A is the voltage scale value, B is the value at which the needle stops, and C is the maximum value on measuring line. The unit of measurement will be according to the scale you are using.

Method 2: Measure the inductor with a multimeter with Ohm scale (Ω)

Step 1: First, you adjust the meter's switching head to the appropriate ohm scale. Then, connect the two measuring leads of the multimeter to the two ends of the inductor to be tested. Note, before measuring, you need to adjust the potentiometer to 0.
Step 2: Monitor the position where the indicator needle stops on the scale, this will be the measured value.
Step 3: To determine the measurement results, apply the formula: R = A x B, where A is the value of the ohm scale and B is the stop value of the indicator needle. The resulting units will depend on the scale you use.

Refer to specialized multimeter models:

To achieve accurate inductor measurement results, you should choose multimeters from reputable brands such as Hioki, Kyoritsu, Fluke, or Sanwa.

In fact, only high-end multimeters have smart features built in to measure inductors. Therefore, the price of these devices is often higher than that of regular multimeters. You can consider choosing products from the above brands to ensure quality and efficiency when working:

In addition, you can also learn more about the multimeter lines capable of accurately measuring inductors distributed at EMIN. This is a reputable supplier specializing in providing genuine electrical measuring equipment from many major brands. Here, you will receive professional advice, helping you choose the product that best suits your needs.

관련 뉴스

Insulation Resistance Tester: Procedures and Safety Precautions
2026년 08월 25일 09시 05분 54초

A megohmmeter must be used according to the proper procedure to ensure operator safety and reliable measurement results. This article covers its operating principle, testing procedure, influencing factors, and essential safety precautions.

How to Measure Ground Resistance Effectively
2026년 08월 25일 09시 02분 07초

A ground resistance tester is used to measure the resistance of a grounding system or ground electrode. Using the correct measurement method gives operators a better basis for identifying changes in the system over time and taking appropriate inspection or corrective measures.

DC Resistance Meter and Considerations When Testing Electrical Equipment
2026년 08월 25일 09시 00분 32초

DC resistance meters are commonly used to evaluate current paths, windings, and contact points characterized by low resistance. The results depend not only on the test object itself but also on the connection configuration, thermal state, inductive characteristics of the windings, and the current injection process.

DC Resistance Meter: Principles and Applications
2026년 08월 25일 08시 58분 25초

DC resistance meter is commonly used in electrical equipment maintenance and system safety testing to evaluate the condition of windings, conductors, and electrical connections.

혜택 소식 받아보기

대량 할인, 도매 가격 업데이트 및 신제품 소식을 이메일로 받아보세요.

구독하면 당사의 서비스 이용약관개인정보 처리방침에 동의하는 것으로 간주됩니다.

빠른 지원

인증된 전문가에게 직접 연결