For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0

EMIN 소식

Comparing Shore A and Shore D Hardness: Two Common Hardness Scales Today
2026년 08월 10일 14시 16분 08초

Both Shore A and Shore D are used to measure material hardness, but each scale is suited to a different group of materials. Soft rubber, silicone, or elastic gaskets are typically tested using Shore A, whereas hard plastics, engineering plastics, and materials with low deformation are better suited to Shore D

What causes equipment to restart automatically in the factory, and how can the fault be identified?
2026년 08월 10일 11시 17분 47초

Equipment restarts in a factory setting can be attributed to voltage sags, momentary power outages, electrical noise, overheating, or hardware faults. For incidents that last only a few power cycles, a power quality analyzer can capture voltage, current, and waveform data at the exact moment of the reset, thereby helping engineers determine whether the power supply is the cause

What Does Record Length Mean on an Oscilloscope ?
2026년 08월 10일 09시 26분 49초

Record length is the number of data points stored during a single waveform acquisition. When the sampling rate remains constant, a longer record length allows the oscilloscope to capture the signal over a longer period of time. Record length affects the actual sampling rate, the ability to maintain a high sampling rate over an extended period, and the amount of data available for electrical waveform analysis.

How an Oscilloscope Probe Works and Why It Matters
2026년 08월 10일 09시 19분 58초

Oscilloscope probes are commonly used alongside other measuring instruments to monitor voltage, frequency, and waveforms. Proper use of the probe ensures greater stability during testing and facilitates more effective signal analysis.

Why Measured Amplitude Can Be Lower Than the Real Value
2026년 08월 10일 09시 11분 49초

Oscilloscope amplitude readings can look lower than expected when the instrument bandwidth is not suitable for the signal. This article explains the basic causes and practical bandwidth choices.

Why Does an Analog Multimeter Needle Move Backward When Measuring Voltage?
2026년 08월 07일 14시 46분 26초

An analog multimeter needle moving backward during voltage measurement does not necessarily indicate a defective instrument. Understanding the operating principle, common causes, and proper inspection procedures helps prevent misdiagnosis and unnecessary repairs.

How to Choose the Right Feeler Gauge
2026년 08월 07일 11시 20분 43초

Learn how to choose and use a feeler gauge correctly to reduce measurement errors during mechanical inspection and maintenance.

Identifying the causes of short-term power outages using a power analyzer.
2026년 08월 07일 10시 28분 40초

A power quality analyzer can record the entire sequence of events—before, during, and after—a momentary power outage. Based on the captured voltage, current, and waveform data, engineers can pinpoint whether the fault originated from the utility grid or the facility's own electrical system, rather than relying on speculation based solely on external symptoms