When to test breakdown voltage? Practical experience from lab to factory

2025년 11월 13일 08시 49분 15초

Breakdown voltage represents the limit to which a material can maintain its insulating ability before a discharge occurs. When this value is reduced, the insulation has lost its stability and there is a risk of short circuit, leakage or equipment failure.

Early inspection helps identify the level of aging, manufacturing deviations or environmental influences, especially in parts working in conditions of heat, humidity, or high electrical loads.

The most obvious practical situations when measuring breakdown voltage

- Production: evaluation of input materials, inspection of components after assembly and before shipment.

- Research: determination of dielectric properties of new materials, comparison of results before and after environmental tests.

- Equipment maintenance: inspection of insulation condition of motors, transformers, capacitors, switching devices or old cables.

Common errors and how to fix them

This measurement is prone to error if not performed correctly. Off-center electrode alignment causes uneven field distribution, leading to premature discharge. Poor grounding of the cable or a humid test environment can cause leakage currents on the surface of the sample. Contaminated or greasy samples can also give lower results than the actual results.

The solution lies in controlling the test conditions: keeping the surface dry and clean, adjusting the electrode gap to a stable level, choosing a consistent voltage ramp rate. In addition, the device needs to be periodically calibrated, because errors in the high-voltage measuring circuit can make the entire result invalid.

Read more about breakdown voltage to understand better: If you don't know about breakdown voltage then here is the answer for you.

When to repeat the measurement. Reasonable inspection schedule

Not all materials require frequent testing, but when operating conditions are severe, it is advisable to establish a clear inspection cycle. For production lines, batch testing is common, with each batch representing a shift or batch of material. For equipment operating continuously, re-testing is usually performed after each maintenance period or when abnormalities such as leaks, sparks, or changes in surface temperature are detected.

The results of each measurement should be recorded to monitor the decreasing trend of the breakdown voltage. When the value is found to be decreasing rapidly, it is the basis for assessing the aging level and planning for replacement before a failure occurs. 

Breakdown voltage testing is not a mandatory operation in every process, but is a key step in understanding the insulation condition of electrical materials and equipment. When the measurement data is collected and managed properly, it becomes the basis for maintaining the safety and reliability of the entire electrical system.

관련 뉴스

What Is Fiber Polarity and How Do You Choose an MPO Method?
2026년 11월 14일 11시 35분 16초

Fiber polarity ensures the transmit path connects to the corresponding receive path. For MPO-based duplex channels, the selected method must remain consistent across trunks, cassettes, adapters, and patch cords.

The scent of new wood in a newly handed-over apartment: How to measure and address formaldehyde (HCHO) levels before moving in
2026년 11월 14일 10시 28분 19초

Many people refer to the pungent, acrid odor that emerges when opening a new cabinet as the "smell of new wood," assuming it will simply dissipate after a few days. In reality, however, what is being released could well be formaldehyde—a substance originating from the adhesives used in the pressed-wood panels—and our sense of smell is not a reliable enough gauge to determine the concentration levels present

Guide to Selecting a TCLP Toxicity Characteristic Leaching Procedure Shaker Configuration in Compliance with QCVN 07:2025/BNNMT and TCVN 9239:2012
2026년 11월 13일 17시 23분 39초

Regulation QCVN 07:2025/BNNMT (replacing QCVN 07:2009/BTNMT and QCVN 50:2013/BTNMT) specifies hazardous waste and sludge thresholds based on leachate concentrations. To ensure that analytical results for heavy metals and organic compounds are accepted during ISO/IEC 17025 or VIMCERTS assessments, laboratories must comply with the Toxicity Characteristic Leaching Procedure (TCLP) specified in TCVN 9239:2012, which is equivalent to US EPA Method 1311

Checking the Temperature of Paint and Coating Surfaces After Curing Using an Infrared Thermometer
2026년 11월 13일 16시 11분 22초

An infrared thermometer allows surface temperature measurement without direct contact, making it suitable for products coming out of curing ovens or surfaces that are difficult to access. However, to ensure reliable results for production quality control, it is important to understand the measurement principle and the factors that affect measurements on painted and coated surfaces.

Crowded Gyms and Yoga Studios: How to Manage Air Quality to Retain Members
2026년 11월 13일 15시 07분 40초

Around 6 or 7 in the evening, the gym becomes packed; the music drowns out the sound of heavy breathing, and the air conditioning runs at full blast behind closed doors. At first glance, everything seems fine: the room is cool, the lights are bright, and the equipment is state-of-the-art. Yet, after just a few sessions, regular members begin to feel a heavy-headedness and find themselves running out of breath more quickly eventually, they simply stop renewing their memberships. No one complains about the personal trainers or the exercise machines. The very thing that makes them feel stifled and drives them away is something entirely invisible: the air inside the room

혜택 소식 받아보기

대량 할인, 도매 가격 업데이트 및 신제품 소식을 이메일로 받아보세요.

구독하면 당사의 서비스 이용약관 및 개인정보 처리방침에 동의하는 것으로 간주됩니다.

빠른 지원

인증된 전문가에게 직접 연결