For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0

2025年10月28日 10時45分26秒

In many cases, the person measuring the device concludes that it is vibrating strongly because of a wrong display unit. By understanding the nature of each un

In many cases, the person measuring the device concludes that it is vibrating strongly because of a wrong display unit. By understanding the nature of each unit, the engineer will know whether the device is really stable or signaling a problem.

3 basic quantities reflecting vibration in industry

Vibration of equipment can be expressed in three main quantities: acceleration, velocity and displacement amplitude. Acceleration, measured in m/s² or g, reflects the vibration level acting on the bearing, suitable for early detection of faults such as ball wear or impact. 

Velocity, expressed in mm/s RMS, is the most widely used unit and is standardized in international standards such as ISO 10816 to assess the overall vibration level of rotating machinery.

Meanwhile, displacement amplitude, measured in microns or mils, is often used for low-frequency machines such as industrial fans or slow-rotating shafts. Each quantity has its own role and you need to understand all of them when working.

Misreading units, misunderstanding device status

A measurement is only meaningful if the unit is understood correctly. If the device is displaying acceleration but the user compares it to the RMS velocity standard, the evaluation result can be many times off. 

In some cases, engineers replace bearings because they think the machine is vibrating too much, when in fact the measurement value only shows high acceleration due to high frequency.

Conversely, if you rely solely on amplitude when measuring high-speed equipment, many signs of bearing damage will be missed. Each unit has its own vibration language, and the reader needs to understand that language correctly to listen for the true condition of the equipment.

Application of ISO 10816 standard and selection of appropriate measurement units

For ISO 10816, RMS velocity is chosen as the reference unit to classify vibration levels into clear levels, from good to dangerous. Using the same unit allows engineers to compare data between multiple devices, even when using different measuring devices. In predictive maintenance systems, synchronizing the measurement unit also helps to store and analyze vibration data consistently. When measuring high-speed devices, the acceleration mode should be preferred to detect faults early. For overall assessment, ISO RMS velocity should be used. 

For low-speed devices, displacement amplitude units will give better results. Many modern meters now allow simultaneous display of all three quantities, making it easy for users to switch when needed. For example, the MMF VM22 Vibration Meter (distributed by EMIN) allows simultaneous measurement of acceleration, velocity and displacement amplitude, this feature helps users flexibly switch measurement units and read more accurate results.

At EMIN, the distributed vibration meters support many display options, helping users to be flexible when measuring and comparing data. 

In addition, you can read more articles below about vibration meters to understand the nature of vibration and choose the most suitable device for you.

Detect and Troubleshoot with Vibration Meter

Faulty Vibration Meters? How to Fix Them

Diagnose Your Device with Vibration Meters

相关新闻

Need a simple fix for weak or unstable voltage? Try a DHVN unit today.
2026年08月06日 14時06分28秒

You can easily check for weak or unstable power right at home using a multimeter. After just a few minutes of measuring the voltage, you will be able to determine whether the power supply is experiencing a voltage drop or if the issue lies with the wiring, the outlet, or the appliance itself.

6 early signs of a burnt start capacitor to avoid losing millions
2026年08月06日 10時34分44秒

"Silent capacitor burnout" refers to a phenomenon where a start capacitor gradually loses capacitance without exploding or emitting smoke, making it difficult for the user to detect the issue until the motor has sustained severe damage. The appliance continues to operate but runs sluggishly, overheats, and consumes twice the normal amount of electricity. Without periodic inspections, a component costing only a few tens of thousands of dong could force you to replace the entire motor, air conditioner compressor, or ceiling fan an expense running into the millions.

Can an analog multimeter still measure capacitors?
2026年08月05日 15時30分41秒

An analog multimeter can still be used to quickly check if a capacitor is shorted, open-circuited, or capable of charging and discharging. However, if precise capacitance measurement or an assessment of capacitor quality is required, a digital multimeter or LCR meter will yield more reliable results

Measuring Pump Shaft Speed? When Is It Necessary, and How Should It Be Done Correctly?
2026年08月04日 14時45分15秒

Measuring pump shaft speed helps determine the equipment's actual rotational speed (RPM), allowing for comparison against design specifications to detect issues such as belt slippage, incorrect gear ratios, abnormal motor operation, or failure to achieve the desired flow rate. Depending on operating conditions, engineers may choose a laser tachometer, a contact tachometer, or a stroboscope

获取优惠更新

获取专属批量折扣、批发价格更新和新产品通知,直接发送到您的邮箱。

订阅即表示您同意我们的服务条款隐私政策

快速支持

直接联系认证专家