Three-phase measurements with PicoLog and PicoScope

2021年11月27日 09時29分42秒

**The test installation** Firgue 1: Installation This summer, Pico’s Business Development Manager Trevor Smith selflessly volunteered to take some oscillosc

The test installation

Firgue 1: Installation

This summer, Pico’s Business Development Manager Trevor Smith selflessly volunteered to take some oscilloscopes and data loggers with him to the south of France. As he was staying in a building with a three-phase mains supply, it seemed like a perfect opportunity to test the Pico equipment and capture some waveforms.

With the main power supply switched off, Trevor hooked up a PicoScope 4444 high-resolution differential oscilloscope to the consumer unit using three PicoConnect 442 1000 V CAT III probes. These probes are rated for use in fixed mains installations on the protected side of the company fuse.

Trevor also installed a PicoScope 4824 8-channel high-resolution oscilloscope equipped with a TA325 three-phase Rogowski coil current probe. The three coils of the TA325 were wrapped around the three supply phases. These probes are highly flexible and therefore easy to install around conductors of any shape without disconnecting the supply.

Finally, Trevor added a PicoLog CM3 current-monitoring data logger with its three AC current clamps. The CM3 runs with the PicoLog software for long-term data logging.

The results

The voltage waveforms show very little distortion, indicating that the supply has a low impedance and is not being overloaded.

The current waveforms are obviously unbalanced. The blue phase is almost sinusoidal, indicating a large resistive load. The red and green phases are smaller in amplitude and non-sinusoidal, suggesting that the loads are switch mode power supplies.

The PicoLog CM3 has plotted the three phase currents over a period of several hours. Here we are interested in the RMS current, not in the 50 hertz current waveforms. The plot shows that the blue phase is drawing a lot more current than red and green. In this case it is not a problem as the current is within the capability of the supply. In a more extreme case it might indicate a need to redistribute the loads among the three phases to prevent overloading any one phase.

Firgue 2: The voltage waveforms

Firgue 3: The current waveforms

Firgue 4: The PicoLog CM3

Conclusion

Pico’s high-resolution oscilloscopes are ideal for capturing mains power waveforms. Both the scopes used here have 12-bit resolution, enabling them to capture highly detailed waveforms and make accurate measurements. They also have deep memory, enabling them to capture long traces at fast sampling rates. This allows you to see high-frequency detail and long-term trends, all in the same waveform.

Our 4-channel oscilloscopes are perfect for capturing three-phase voltage or current waveforms. If you need to capture both types of waveform at once, use the 8-channel PicoScope 4824.

All Pico oscilloscopes can be used with industry-standard probes and other accessories. (The PicoScope 4444 requires additional adaptors).

The PicoLog software works with all Pico data loggers including the PicoLog CM3. It is the best choice for logging over long periods of time, as it has a robust file format that can survive unexpected shutdowns and is efficient at handling very large data sets.

相关新闻

What Is Resonant Frequency? Why Can a Single Frequency Range Damage the Entire Product?
2026年07月10日 15時10分46秒

A device may operate stably for months, yet suffer cracks, broken solder joints, or snapped component leads after being transported. What surprises many engineers is that the vibration amplitude during transport is no greater than usual. The root cause lies in a specific frequency range where the product's structure absorbs energy most intensely, triggering resonance and causing continuous stress concentration at a single point.

Should Carton Packaging Undergo Vibration Testing or Drop Testing First?
2026年07月10日 10時38分40秒

Một kiện hàng gần như không bao giờ bị rơi ngay khi vừa rời khỏi nhà máy. Quãng đường hàng trăm kilomet trên xe tải, container hay băng chuyền mới là giai đoạn diễn ra đầu tiên, nơi bao bì liên tục chịu rung lắc trong nhiều giờ. Chỉ sau đó mới đến những cú va chạm khi bốc xếp, giao nhận hoặc rơi ngoài ý muốn.

Distinguishing Between DFT and WFT in Coating Thickness Measurement
2026年07月09日 14時40分30秒

Many projects encounter a situation where a freshly applied coating looks perfectly uniform and paint consumption matches the estimate, yet additional coating is required during inspection because the thickness is insufficient. This leads many to suspect measurement errors or equipment inaccuracy, whereas the actual cause is a confusion between WFT (Wet Film Thickness) and DFT (Dry Film Thickness)

Can a car paint thickness gauge detect if a vehicle has been in a collision?
2026年07月08日 16時56分01秒

Many used car buyers often spend a considerable amount of time examining the paintwork, the gaps between body panels, or the overall condition of the exterior. However, these signs can be skillfully masked following repairs; precise color matching and careful polishing can make the vehicle appear almost factory-original.

获取优惠更新

获取专属批量折扣、批发价格更新和新产品通知,直接发送到您的邮箱。

订阅即表示您同意我们的服务条款隐私政策

快速支持

直接联系认证专家