Rules regarding safe distances from high-voltage power lines according to current law.

2026年01月15日 14時16分13秒

Understanding the concept of high voltage and safe distances from power grid corridors is a mandatory requirement for the inspection, maintenance, and construction of high-power electrical systems. The higher the voltage, the greater the risk of electrical discharge through the air, requiring strict adherence to technical safety regulations.

What is high voltage?

High voltage electricity is an electrical system with a high voltage level, capable of causing serious danger to people and equipment even without direct contact. According to the currently applied classification, high voltage electricity typically starts at levels above 35 kV.

In Vietnam, the commonly used high voltage levels include 110 kV, 220 kV, and 500 kV. These are voltage levels belonging to the national power transmission system, responsible for delivering electricity from power plants to intermediate substations and major consumption areas.

High-voltage power grids use bare conductors suspended on utility poles via strings of insulators. This structure helps reduce power loss but also increases the risk of electrical discharge when approached at close range.

Characteristics of high-voltage power grids

High-voltage power systems require strict technical standards to ensure stable operation and safety. The conductors are uninsulated, and the distance between the conductors and the ground and surrounding structures is calculated based on the discharge capacity at each voltage level.

High-voltage power poles typically use centrifugal concrete poles, steel tower poles, or specialized poles, with common heights of 18 meters or more. This height helps maintain a safety corridor, minimizing impact on people, vehicles, and structures below.

High voltage safe distance

High voltage electricity has the potential to discharge through the air; therefore, safe distances are not only determined by direct contact but also depend on the voltage level and the surrounding environment. Current regulations clearly define the minimum distance between high-voltage power lines and roads, railways, and inland waterways.

1. Safe distance for 35 kV high voltage power lines.

For 35 kV power lines, the minimum safe distance to road vehicles is 2.5 m. For railways and other electrical installations, the minimum required distance is 3 m. In inland waterways, a distance of 1.5 m at the lowest point of sag must be ensured.

2. Safe distance for 110 kV high voltage power lines.

At 110 kV voltage level, the safe distance from roads is maintained at 2.5 m. Railways and other electrically powered transportation infrastructure must maintain a minimum distance of 3 m. Inland waterways require a distance of 2 m.

3. Safe distance for 220 kV high voltage power lines.

220 kV power grids have a higher potential for electrical discharge, therefore the safety distance must be increased. Roads require a minimum distance of 3.5 m. Railways and power transmission infrastructure require 4 m. Inland waterways require a distance of 3 m.

4. Safety corridor distance for 500 kV power grid

At the 500 kV voltage level, safety regulations are much stricter. Road vehicles need to maintain a minimum distance of 5.5 m. Railways and electrically powered transport infrastructure require 7.5 m. Inland waterways require a distance of no less than 4.5 m.

Learn more about low voltage electricity: What is low voltage electricity? What are the current regulations regarding safe distances for low voltage electricity?

Safety principles when approaching high-voltage power lines.

High-voltage power lines pose a risk of electrical discharge even without touching the conductors. Therefore, basic safety principles must be strictly adhered to.

Do not approach high-voltage power lines at a distance less than the permitted distance. Do not climb power poles, and do not touch conductors or objects suspected of being conductive located near power lines.

Avoid using long metal equipment such as ladders, cranes, forklifts, or antennas near power line corridors. These items can easily become conductors of electricity when they get too close to high-voltage lines.

Do not excavate, construct, or renovate structures near power poles without permission from the power management authority. High-voltage power pole foundations are deep and directly affect the stability of the entire line.

Upon discovering a broken power line, electrical discharge, or any unusual signs on a power pole, maintain a safe distance and immediately notify the power company. Do not approach or handle the situation using ordinary means.

Measuring equipment to support high-voltage electrical work.

In high-voltage environments, assessing voltage and load current conditions requires specialized measuring equipment that meets insulation safety and field stability requirements. The electrical measuring equipment distributed by EMIN effectively meets these needs.

The Fluke 117 multimeteris widely used for testing AC voltage, DC voltage, and continuity in electrical cabinets, substations, and auxiliary systems of high-voltage power grids. The device meets CAT III 600 V safety standards, making it suitable for industrial electrical environments.

For non-contact current measurement needs, the Fluke 323 clamp meter is a suitable choice for electrical engineers requiring quick assessment of load current on conductors without directly interfering with the circuit. This clamp meter is well-suited for AC current measurement applications in transmission and distribution systems.

For non-contact current measurement, the Kyoritsu 2117R clamp meter is also widely used in testing leakage current and load current in power lines and industrial switchgear. The device supports quick measurements, convenient operation, and is suitable for routine maintenance.

相关新闻

What Is Resonant Frequency? Why Can a Single Frequency Range Damage the Entire Product?
2026年07月10日 15時10分46秒

A device may operate stably for months, yet suffer cracks, broken solder joints, or snapped component leads after being transported. What surprises many engineers is that the vibration amplitude during transport is no greater than usual. The root cause lies in a specific frequency range where the product's structure absorbs energy most intensely, triggering resonance and causing continuous stress concentration at a single point.

Should Carton Packaging Undergo Vibration Testing or Drop Testing First?
2026年07月10日 10時38分40秒

Một kiện hàng gần như không bao giờ bị rơi ngay khi vừa rời khỏi nhà máy. Quãng đường hàng trăm kilomet trên xe tải, container hay băng chuyền mới là giai đoạn diễn ra đầu tiên, nơi bao bì liên tục chịu rung lắc trong nhiều giờ. Chỉ sau đó mới đến những cú va chạm khi bốc xếp, giao nhận hoặc rơi ngoài ý muốn.

Distinguishing Between DFT and WFT in Coating Thickness Measurement
2026年07月09日 14時40分30秒

Many projects encounter a situation where a freshly applied coating looks perfectly uniform and paint consumption matches the estimate, yet additional coating is required during inspection because the thickness is insufficient. This leads many to suspect measurement errors or equipment inaccuracy, whereas the actual cause is a confusion between WFT (Wet Film Thickness) and DFT (Dry Film Thickness)

Can a car paint thickness gauge detect if a vehicle has been in a collision?
2026年07月08日 16時56分01秒

Many used car buyers often spend a considerable amount of time examining the paintwork, the gaps between body panels, or the overall condition of the exterior. However, these signs can be skillfully masked following repairs; precise color matching and careful polishing can make the vehicle appear almost factory-original.

获取优惠更新

获取专属批量折扣、批发价格更新和新产品通知,直接发送到您的邮箱。

订阅即表示您同意我们的服务条款隐私政策

快速支持

直接联系认证专家