Current Analyzer Speeds Medical Device Evaluation by 50 Percent

2021年03月09日 17時14分55秒

The instrument’s wide dynamic range, up to 16-bits resolution, allows for easy capture of a device’s dynamic current - from sleep mode to active mode.

The progress in modern medical care is remarkable. Increasing development of Internet of Things (IoT) devices for the medical industry is a key factor in that progress. In recent years, pacemakers, defibrillators, and other medical device implants have gotten smaller and smarter. They monitor biometric information like a patient’s heartbeat (HR), blood pressure (Bp), blood sugar/glucose level (BS/BD), and blood oxygen saturation (SpO2). The medical data they collect travels through the internet via Bluetooth™ Low Energy (BLE), WiFi, or some other wireless communication protocol, providing doctors real-time diagnostic information.

While medical devices bring a host of benefits to patients and doctors alike, they also create new challenges for the engineers developing them. One such R&D team at a large multinational medical electronics company recently discovered how difficult it is to develop a smart, implantable medical device. They struggled to balance designing a high quality, reliable device with long battery life in a shorter development time frame. Using Keysight Technologies’ CX3300 Series Device Current Waveform Analyzer, the engineering team was able to optimize device battery life, detect previously undetected defects, and speed device evaluation.

Conflicting Priorities in Smart Medical Device Design

Various issues make developing a smart medical device challenging. These issues include:

1. Reducing the device design and validation period to ensure quick delivery of new products to the marketplace. With any medical device, certification is a requirement for use. Evaluation data is necessary for device certification. While efficiently capturing and analyzing evaluation data is difficult, it is critical to identify defects prior to shipping a device. Without accurate, repeatable data or sufficient evaluation, critical device defects can be overlooked. In a medical device, a defect can negatively impact a patient’s outcome. In the worst-case scenario, it can even result in death.

2. Lowering power consumption to reduce a device’s battery replacement cycle. For battery-operated medical devices that are implanted, battery replacement requires surgical intervention. It’s a key reason engineers need to optimize the battery life of their devices. Power consumption can be reduced using an intelligent power management program to switch between multiple sleep modes, but adding this into the medical device requires additional evaluation and verification to ensure the program operates as expected.

Adequately collecting and analyzing evaluation data and lowering device power consumption are goals often at odds with the engineer’s need to get new medical devices to market quickly. Accomplishing these tacks requires accurate and in-depth measurement of the device’s current waveform.

Measurement Challenges

In a conventional current waveform measurement, an oscilloscope and current probe or differential probe with shunt resistance, are typically used. Unfortunately, the noise coming from the test equipment can negatively impact the accuracy and measurement repeatability required for device certification. Also problematic is that the bandwidth of high-precision, low-noise measurement equipment is often too narrow. As a result, the fast spikes or inrush currents that lead to device failure can easily go unnoticed.

Another challenge engineers face, especially when validating the intelligent power management of a medical device during operation, is the need to measure the current waveform from a low sleep current (< 1 mA) to a high-current active mode without missing any signals.

Complicating matters, traditional current waveform measurement is:

- Inefficient. Test equipment often lacks a broad dynamic range, forcing engineers to re-measure by switching the shunt resistances for the various measurement ranges. Validating the software program becomes a series of activities, and the possibility of missing issues hidden in the operation is high.

- Time Consuming. Data post-processing, such as noise reduction or combining data from multiple instruments, is required. These processes alone can take hours or days to finalize. With medical device certification requiring extensive measurement data and analysis, reducing the evaluation period is difficult at best.

Faster, More Accurate Measurement

For an answer to these challenges, the R&D team turned to Keysight Technologies with its CX3300 Series Device Current Waveform Analyzer (Figure 1). The instrument’s wide dynamic range, up to 16-bits resolution, allows for easy capture of a device’s dynamic current - from sleep mode to active mode. Its low measurement noise means that even small signals can be detected. A wide - bandwidth current measurement, up to 200 MHz, accurately captures fast spikes and inrush currents that cause circuit failure, while an extended memory depth of up to 256Mpts/ch ensures elusive defective waveforms are captured. Such capabilities enable both efficient and accurate current profile measurement and analysis, all in one instrument.

Keysight's CX3300 Anomalous Waveform Analytics Contributes to Waseda  University's Hardware Trojan Detection Research | Keysight

Figure 1: CX3300 characterizes, validates, and debugs medical devices

To validate the operation of its medical implantable device, the R&D team used multiple instruments and shunted resistances within the current operating range. The team then summarized the measurement results into one operating waveform in the post-processing phase.

Using the CX3300, the team quickly captured the necessary current waveforms within a single unit and generated the simulation data using Keysight’s automatic current profiler. This drastically reduced the evaluation device certification period and allowed the engineering team to quickly and easily identify and resolve a software defect in the control program.

A Better Plan For The Future

Using Keysight’s CX3300, the R&D team quickly and accurately characterized, validated, and debugged a smart implantable medical device, effectively reducing the evaluation period for certification by 50%. The team also quickly located and resolved previously undetected software bugs in the design that were causing power management issues. The medical electronics company now has a solution for easily and efficiently capturing accurate current waveforms, while reducing the time to analyze the data, giving it a time-to-market edge in the highly competitive medical device marketplace.


相关新闻

EMIN Becomes an Official Distributor of ZEISS in Vietnam Starting July 2026
2026年07月24日 15時35分27秒

Starting in July 2026, EMIN officially became an Authorized Distributor of ZEISS in Vietnam. With a history spanning more than 175 years, ZEISS is recognized as one of Germany's technology companies and a global pioneer in the fields of optics and optoelectronics. The company provides advanced solutions for industrial manufacturing, scientific research, healthcare, semiconductor production, and quality assurance.

How Does Fluke Help Factories Detect Hard-to-Spot Electrical Risks?
2026年07月24日 14時23分04秒

The more high-capacity machinery a factory houses and the more complex its power supply network becomes, the harder it is for routine checks such as voltage measurements or visual inspections of electrical cabinets to fully reflect the safety status.

Which products are tested using a -40°C to +150°C thermal shock chamber?
2026年07月22日 14時45分25秒

Automotive circuit boards, sensors, modules, and plastic components can all experience issues after repeated transitions between cold and hot environments. A thermal shock chamber operating from -40°C to +150°C enables the replication of these temperature fluctuations under controlled testing conditions.

Does thermal shock cause damage to electronic components?
2026年07月22日 10時40分49秒

An electronic component may operate stably under constant temperature conditions yet fail after repeated rapid transitions between hot and cold. The issue typically stems not from a specific temperature level, but rather from the rate of temperature change and the number of hot-cold cycles

The rigorous standards behind a multi-million-dollar MRI suite
2026年07月21日 14時54分01秒

An MRI system may be correctly installed and fully connected to the power supply, yet still encounter issues if the surrounding environment fails to meet technical specifications. Electromagnetic interference, RF shielding, power quality, grounding, temperature, humidity, and particulate levels are all factors that may require assessment, depending on the facility's design and the manufacturer's requirements.

获取优惠更新

获取专属批量折扣、批发价格更新和新产品通知,直接发送到您的邮箱。

订阅即表示您同意我们的服务条款隐私政策

快速支持

直接联系认证专家