Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts
Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.
By subscribing, you agree to our Terms of Service and Privacy Policy.
Direct access to our certified experts

- High Voltage Output Range (Adjustable Regulated, Positive or Negative Output): 0 ~ 30000VDC
- High Voltage Outputs: Single Unipolar
- Input Voltage: Nominal, 24 VDC
- Power Output (Watts, Nominal): 4 W, 15 W, 30W
DC Input
- Vin (Input Voltage) Range: 23 ~ 30VDC
- Iin (Nominal):
100% HVout, 100% LOAD: 0.5A, 1.1A, 1.8A
100% HVout, 0% LOAD: < 0.3A
Disable/standby state: < 0.08A
DC Output
- Iout (Output Current): (max) @ 0~ 100% HVout, Vin (nominal), 0.13mA, 0.50mA, 1.00mA
- Pout (Output Power): max, 4W, 15W, 30W
- Ripple @ Full LOAD, Max Eout: <0.002%
Stability and Regulation
- Stability:
0.01% (100 ppm) @ 100% HVout (per 8 h interval, after 30 min warmup)
- Line Regulation: 0.0025% (25 ppm) @ 100% HVout, 100% Pout
- Static Load Regulation: 0.0025% (25 ppm) @ 100% HVout, Load Step, 0 ~ 100%
- Temperature Coefficient: 25 ppm/°C (standard configuration over operating temperature range)
- Power-On Rise Time:
< 750 msec @ 100% LOAD
Contact factory for other options.
Environmental
- Operating Temperature Range: 10 ~ 45°C (50 ~ 113°F) case temperature @ 100% HVout, 100% LOAD
- Storage: -55 ~ 105°C (-67 ~ 222°F) case temperature
- Humidity: 0 ~ 95% RH, non-condensing
- Altitude: Sea level to 2000 m (6562 ft)
- Certifications: UL/cUL recognized, IEC-62368-1, CE mark (LVD and RoHS)
Volumes and Weights:
- Volume (Module body only): 705cm3, 43in3
- Weight (Standard Configuration): 1322g, 46.6oz
Options & Accessories:
- -10PPM: Upgrades module temperature coefficient rating from 25 ppm/°C to 10 ppm/°C for enhanced high-voltage output stability over standard
operating temperature ranges.
- -AZ: Enhances the stability of module high voltage output at setpoints below <10% HVout by optimizing performance. (Available only on 4 W models).
- -DAF: Replaces male DA-15 Type connector at with female DA-15 Type connector to ease system retrofit and integration tasks
- -LGH: Replaces standard front panel HVout flying lead and ground stud with rear panel mounted LGH Type 1/2L conn
- -SHV: Replaces standard front panel HVout flying lead and ground stud with rear panel mounted SHV-5KV connector and ground stud. (Available only on 1 to 4 kV units).
- -BNC: Replaces standard front panel HVout flying lead and ground stud with rear panel mounted BNC-10KV connector and ground stud. (Available only on 1 to 10 kV units)