Ainuo ANFS030A(F) AC Power Supply (30kVA, 45.4A, 300.0V)
Manufacturer: Ainuo Model: ANFS030A(F) - Request a Quotation
- Contact
See more: Equipment Calibration-Inspection & Repair Service
Call for the best price
Hanoi city: (024) 35.381.269
Danang city: (023) 63.747.711
Bac Ninh city: (0222) 730.39.68
Hai Phong city: (0225) 730.03.89
HCM city: (028) 38.119.636
Dong Nai: 0345.689.536
Input: 3-phase 4-wires,AC: 380V±57V,50/60Hz±3Hz
Output Capacity: 30kVA
Output Frequency: 45.0~240.00Hz
Frequency Stability: ≤0.02%
Output Mode: 3 phaes mode, Seperated 3 phaes mode,parallel mode
Output Current: 45.4A
Line Regulation: ≤1%
Load Regulation: ≤1%
Phase retardation: 120°+2°
Modulating voltage range: ≤3V
Protection Mode: IGBT hot, IGBT OverCurrent, Transformer hot, Input Lack Voltage, Input Over Voltage, Output Lack Voltage, Output Over Voltage, Output Over Current, Output Over Power, Lack Output Phase
Voltage Drop Compensation: 0.000~0.500Ω
Communication:RS232(Standard), RS485(Options), GPIB(Options),Ethernet(Options)
Remote Control:Analog Control(Options)
Dimension W×H×D(mm): 600*1130*1018
Weihgt (kg): 330
Product Detail
Main features
* Adopt FPGA digital technology,realize precision control and high quality sine wave output;
* Advanced power output mode management:standard three-phase output,separated three-phase output(three-phase voltage and frequency adjusted independently), parallel single-phase output(three phase parallel,single-phase output)to achieve multi-function;
* Operating in over current shock(up to 3 times of rated current) within 2s,start the impact load of 1/3 capacity of powersupply directly;
* Adjustable voltage and frequency during output status,frequency change without transit time;
* Online monitoring:monitor IGBT temperature,transformer temperature,fan speed,input voltage and other parameters during output status;
* Operating data recorders:keep the record of power supply status and alarm code automatically during alarming,save the maintencance time;
* Fan speed will be adjustable automatically with the temperature of power supply to reduce the noise;
* Lock key,user-friendly design,automatically locking without operation for 5 minutes to prevent from opreation mistakes,
* 8 inch color LCD screen;
* Standard RS232,optional RS485,GPIB,Ethernet,analog control and other remote communication/control.
Order and Extensions
* ANFC three-phase AC pwer supply:1.0-300.0v/45.0-65.0HZ,100HZ,120HZ,200HZ,240HZ,optional 15kva,30kva,45kva,60kva,90kva,120kva,180kva,240kva.larger capacity can be modified.
* Communication interfaces:Standard RS-232, optional RS485,GPIB,Ethernet(Remarks:only can select one of RS-232,RS-485,GPIB,Ethernet).
* Remote control interface:optional analog control interface.
* PC control software
Spec.
Model/Specification |
ANFS015A(F) |
ANFS030A(F) |
ANFS045A(F) |
ANFS060A(F) |
ANFS090A(F) |
ANFS120A(F) |
ANFS180A(F) |
ANFS240A(F) |
|
Input |
3-phase 4-wires,AC: 380V±57V,50/60Hz±3Hz |
||||||||
Output Capacity |
15kVA |
30kVA |
45kVA |
60 kVA |
90 kVA |
120 kVA |
180kVA |
240KVA |
|
Output Frequency |
45.0~240.00Hz |
||||||||
Frequency Stability |
≤0.02% |
||||||||
Output Mode |
3 phaes mode, Seperated 3 phaes mode,parallel mode |
||||||||
Output Current |
110V |
45.4A |
90.9A |
136.3A |
181.8A |
272.7A |
363.6A |
545.4A |
727.2A |
220V |
22.7A |
45.4A |
68.2A |
90.9A |
136.3A |
181.8A |
272.7A |
363.6A |
|
Accuracy |
Voltage |
Resolution:0.1V Accuracy:0.2%×reading+0.2%×F.S. (45Hz—65Hz) |
|||||||
Current |
Resolution:0.1A/1A Accuracy:0.3%×reading+0.3%×rated output |
||||||||
Frequency |
Resolution:0.1Hz Accuracy:0.05% |
||||||||
Power |
Resolution: 0.1kW / 0.01kW / 0.001kW Accuracy: 0.45%×reading+0.45%×F.S. (45Hz—65Hz) |
||||||||
Line Regulation |
≤1% |
||||||||
Load Regulation |
≤1% |
||||||||
Voltage Distortion |
Linear load: THD<1.5%(110V±10%,220V±10%,45-65Hz); |
||||||||
Transient time |
20ms |
||||||||
Phase retardation |
120°+2° |
||||||||
Phase unbalance factor |
≤1% |
||||||||
Crest factor |
1.41±0.1 |
||||||||
Modulating voltage range |
≤3V |
||||||||
Over Power |
105%≤Output<110% the output will be stopped within 15 Sec. 110%≤Output<210% the output will be stopped within 5 Sec. 200%≤Output<300% the output will be stopped within 2 Sec. 300%≤Output the output will be stopped immediately |
||||||||
Protection Mode |
IGBT hot、IGBT OverCurrent、Transformer hot、Input Lack Voltage、Input Over Voltage、Output Lack Voltage、Output Over Voltage、Output Over Current、Output Over Power、Lack Output Phase |
||||||||
Voltage Drop Compensation |
0.000~0.500Ω |
||||||||
Softstart Time |
0.0~99.9S |
||||||||
Efficiency |
>86% |
||||||||
Shortcut Group |
7 groups |
||||||||
Online Voltage Adjustment |
The output voltage and frequency(45-65Hz) can be adjusted online under running status. |
||||||||
Communication/ Remote Control |
Communication:RS232(Standard)、RS485(Options)、GPIB(Options)、Ethernet(Options)<sp |