DCV: 50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V /0.025 %
ACA (True RMS): 50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V /0.4 %
DCA: 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A /0.06 %
ACA (True RMS):500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A /0.6%
Temperature: -200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F) (option probe)
R: 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ /0.05 %
C: 1.000 nF,10.00 nF 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 1000 µF, 10.00 mF, 100.00 mF /1.0 %
F: 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz /0.005%
Multiple on-screen displays: Yes
True-rms AC bandwidth : 100 kHz
DBV/dBm: Yes
Conductance : 50.00nS
Continuity beeper: Yes
Peak: 250 μS
Elapse time clock: Yes
Time of day clock: Yes
Min-Max-Avg: Yes
Duty Cycle: 0.01 % to 99.99 %
Pulse Width: 0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms
Hold : Yes
Isolated Optical Interface: Yes
Auto/Touch Hold: Yes
Reading memory: Yes
Log to PC: Yes
Interval/Event Logging: Yes
Logging Memory : Up to 10,000 readings
Size: (HxWxL 22.2 cm x 10.2 cm x 6 cm
Weight: 870.9 g (28 oz)
Battery type: 6 AA alkaline batteries
include: Manual, 6 AA Batteries, installed, TL71 Silicone Test Leads, Probe Holder, Two AC175 Alligator Clips
Specifications | |||||||||||||||||||||||||||||||||||||||
Voltage DC |
|
||||||||||||||||||||||||||||||||||||||
Voltage AC |
|
||||||||||||||||||||||||||||||||||||||
Current DC |
|
||||||||||||||||||||||||||||||||||||||
Current AC |
|
||||||||||||||||||||||||||||||||||||||
Temperature (excluding probe) |
|
||||||||||||||||||||||||||||||||||||||
Resistance |
|
||||||||||||||||||||||||||||||||||||||
Capacitance |
|
||||||||||||||||||||||||||||||||||||||
Frequency |
|
||||||||||||||||||||||||||||||||||||||
Additional functions/features |
|
Environmental Specifications | |||||||
Operating Temperature |
|
||||||
Storage Temperature |
|
||||||
Relative Humidity |
|
||||||
Electromagnetic Compatability |
|
||||||
Vibration |
|
||||||
Shock |
|
Safety Specifications | |||
Overvoltage category |
|
||
Agency Approvals |
|
Mechanical & General Specifications | |||
Maximum voltage between any terminal and earth ground |
|
||
Size |
|
||
Weight |
|
||
Battery Life |
|
||
Battery type |
|