Gastec 91D Passive Dosl Tubes Formaldehyde HCHO (0.1 ~ 20 ppm)
Manufacturer: Gastec Model: 91D Origin: Japan - Request a Quotation
- Contact
See more: Equipment Calibration-Inspection & Repair Service
Call for the best price
Hanoi city: (024) 35.381.269
Danang city: (023) 63.747.711
Bac Ninh city: (0222) 730.39.68
Hai Phong city: (0225) 730.03.89
HCM city: (028) 38.119.636
Dong Nai: 0345.689.536
Indicator: 1 ~ 20 ppm
Measuring Range: 0.1 ~ 20 ppm
Sampling Hours: 1 to 10 hours
Colour Change: Yellow → Reddish Brown
Reaction Principle: 3HCHO + (NH2OH)3 H3PO4 → H3PO4, H3PO4 + Base+Phosphate
Coefficient of Variation: 10% (1 ~ 20 ppm-hr)
Nr. of tests: 10
Measuring Range | 0.1 to 20 ppm |
Sampling Hours | 1 to 10 hours |
Detecting Limit | 0.05 ppm (10 hours) |
Colour Change | Yellow → Reddish Brown |
Reaction Principle |
3HCHO + (NH2OH)3 H3PO4 → H3PO4 |
Coefficient of Variation | 10% (for 1 to 20 ppm-hr) |
Shelf Life | 1 Year |
Corrections for temperature & humidity | Unnecessary |
Store the tubes in the refrigerator to keep at 10ºC (50ºF) or below. |
Substance | Interference | Change colour by itself to |
Aldehydes, Ketones, Acid gases | + | Reddish brown |
Substance | Correction Factor | Sampling Time | Measuring Range |
Acetaldehyde | 1.0 | 1 to 10 hours | 0.1 to 20 ppm |
Furfural | 3.0 | 1 to 10 hours | 0.3 to 60 ppm |
Methyl ethyl ketone | 1.25 | 1 to 10 hours | 0.125 to 25 ppm |
Calibration gas generation | Diffusion tube method |
TLV-TWA | TLV-STEL | Explosive range |
- | C 0.3 ppm | 7.0 to 73% |