Metrohm ProfIC Vario 2 Cation Professional Ion chromatography system (Metrohm Inline Ultrafiltration; conductivity detection)
Manufacturer: Metrohm Model: ProfIC Vario 2 Cation - Contact
See more: Equipment Calibration-Inspection & Repair Service
Call for the best price
Hanoi city: (024) 35.381.269
Danang city: (023) 63.747.711
Bac Ninh city: (0222) 730.39.68
Hai Phong city: (0225) 730.03.89
HCM city: (028) 38.119.636
Dong Nai: 0345.689.536
The Professional IC Vario system with Metrohm inline ultrafiltration and conductivity detection enables fully automatic determination of cations or anions (non-suppressed).
Typical areas of application:
Samples with slight to moderate contamination with particles, algae, or bacteria
Drinking and surface water
Process and waste water
High-pressure pump: Serial dual-piston pump with two valves and flow range-optimized, intelligent pump heads
− Flow rate: 0.001–20 mL/min
Injection valve:
− Internal loops: 0.25, 1 μL
− Sample loops: 1.5, 5, 10, 20, 50, 100, 250, 1'000 μL
Column thermostat:
− Temperature range: 0...+80 °C (ambient temperature -20...+50 °C)
− Stability: <0.05 °C
Suppressors: «MSM», «MSM-HC» and «MSM-LC»
Detectors: Among other things, these can be optionally integrated in the system:
− Conductivity detection
− UV/VIS detection
− Amperometric detection
Conductivity detector: Intelligent high-performance conductivity detector
− Design: Detector block (2.850.9010) or stand-alone detector (2.945.0010)
− Measuring principle: DSP – «Digital Signal Processing»
− Measuring range: 0–15'000 μS/cm – without range switching
− Electronic noise : <0.1 nS/cm (at 1 μS/cm)
− Baseline noise: <0.2 nS/cm (e.g. A Supp 5, standard conditions)
UV/VIS detector: Professional UV/VIS diode array detector
− Design: Stand-alone detector 2.947.0010 (SW), 2.947.0020 (MW)
− Wavelength: Single Wavelength (SW) or Multi Wavelengths (MW), 8 wavelengths in the range 190–900 nm (increment 1)
− Bandwidth: 1–50 nm (increment 1)
− Integration duration: 10–247 ms
− Duration of measurement: 50–2’000 ms
− Measuring principle: Diode array with 512 diodes
Amperometric detector: Microprocessor-controlled amperometric detector
− Design: Detector block (2.850.9110) or stand-alone detector (2.945.0020)
− Detection mode: DC, PAD, flexIPAD, CV
− Potential range: –5.0 to +5.0 V in 0.001 V steps
Peristaltic pumps:
− Rotational speed: 0–42 rpm in steps of 6 rpm
− Shift direction turning: Clockwise and counterclockwise
Automation:
− Combinable autosampler:
858 Professional Sample Processor, 919 IC Autosampler plus,
863 Compact IC Autosampler, 889 IC Sample Center, 814 USB Sample
Processor, 815 Robotic USB Sample Processor XL
Control: MagIC Net Professional and Multi ion chromatography software
Scope of delivery
1 PCS 2.850.9010 IC Conductivity Detector
1 PCS 2.858.0020 858 Professional Sample Processor – Pump
1 PCS 2.940.1100 940 Professional IC Vario ONE
1 PCS 6.05330.010 IC equipment: Inline Ultrafiltration 2 - pull mode
- Quality Engagement
- Easy change and return
- Delivery Avaliable
- Favorable payment