Three phase voltage , current , power factor, power, energy calibrator
- DC/AC voltage
+ Summary range: 1 to 600 Vac, 1 to 280 Vdc
+ Voltage resolution: 5 dig.
+ Frequency range: DC, 15 Hz to 1000 Hz
+ Frequency uncertainty: 0.005%
+ Frequency resolution: 0.001 Hz below 500 Hz, 0.01 Hz below 1000 Hz
+ Distortion: < 0.05 %
- DC/AC current
+ Summary range: 8 mA to 30 A
+ Current resolution: 5 dig.
+ Frequency range: DC, 15 Hz to 1000 Hz
+ Frequency uncertainty: 0.005%
+ Frequency resolution: 0.001 Hz below 500 Hz, 0.01 Hz below 1000 Hz
+ Distortion: < 0.1 %
- Phase and power factor
+ Phase range: 0.0° to 359.99°
+ Frequency range: 15 Hz to 1000 Hz
+ Phase resolution: 0.01°
+ Power factor range: -1 to +1 (Lead, Lag)
+ Power factor resolultion: 0.001
- DC power
+ Summary range: 0.008W to 8400 W (420 kW with current coil option 140-50)
+ Power unit: W
- AC power
+ Summary range: 3x (0.008VA to 18 kVA (900 kVA with current coil option 140-50))
+ Frequency range: 15Hz to 1000 Hz
+ Power unit: W, VA, VAr
- DC/AC energy
+ Voltage range: 1 to 280 Vdc (600 Vac)
+ Current range: 8 mA to 30 A
+ Power factor range: - 1 to + 1
+Time range: 1 s to 10 000 s
+ Time resolution: 0.1 s
+ Time interval uncertainty: 0.01 % + 0.1 s
- Multimeter
+ DC voltage 0 to ±12 V / 0.01 % + 0.01 %
+ DC current 0 to ±25 mA/ 0.01 % + 0.01 %
+ Frequency 1 Hz to 15 kHz / 0.005 %
- Non harmonic signals
+ Harmonic and interharmonic distortion (H/I products)
+ Fundamental harmonic frequency range: 15 Hz to 1 kHz
+ Fundamental harmonic amplitude uncertainty: 0.2 % of range
+ Harmonics (2-50) frequency range: 30 Hz to 5 kHz
+ Interharmonic frequency range: 15 Hz to 1 kHz
+ Max. of harmonic products: 50
+ Number of interharmonic products: 1
+ Frequency uncertainty: 0.005 %
+ Amplitude range of H/I products: max. 30% of RMS output value
+ Amplitude resolution of H/I products: 0.001 %
+ Noise & Distortion: - 60 dB
+ Dimensions: 500 x 520 x 430 mm
- Modulation (Flicker)
+ Fundamental harmonic frequency range: 15 Hz to 1 kHz
+ Single harmonic (2-50) frequency range: 30 Hz to 5 kHz
+ Modulation frequency range: 0.001 Hz to 50 Hz
+ Modulation depth: 0 to 30%
+ Modulation depth resolution: 0.001%
+ RMS amplitude uncertainty: 0.2 % of range
+ Waveform of modulation signal: sinus, rectangular
+ Modulation depth accuracy: 0.2 %
Netto weight: 59 kg
Power supply: 115/230V – 50/60 Hz
Power consumption: max. 1500 VA
Included:
Power cable 1 pc
Option 10 Test cable banana-banana 1m 1000V/32A black: 3 pcs
Option 11 Test cable banana-banana 1m 1000V/32A red: 3 pcs
Option 12 Test cable banana-banana 1m 1000V/32A blue: 3 pcs
Option 13 Test cable banana-banana 1m 1000V/32A yellow : 3 pcs
RS232 cable 1.5m: 1 pc
Spare fuse: 1 pc
Option 133-01 High current adapter: 1 pc
Operation manual, CD" 1 pc
Test report: 1 pc
The Model MC133C is a compact single housed three phase electric power/energy calibrator. It can supply the device under test with precision one phase AC voltage and current with calibrated phase shift along with DC voltage and current. Output voltage can be set in five ranges up to 280V and output current in six ranges up to 30A. MC133C calibrator offers two types of defined distortion of its main sinusoidal output signal. The first distortion is based on adding defined amounts of harmonic or inter-harmonic spectral components up to 5kHz. The second type of distortion is based on amplitude modulation of its output sinusoidal signal by a sine or square-wave modulation over the frequency range from 0.001Hz to 50Hz. Maximum depth of modulation is 30%. Using a supplied cable adapter the current outputs can be joined together offering single phase current to 90A AC/DC. |
|
General Technical Data |
|
Voltage range (sine mode) | 1V to 280V AC or DC |
Current range (sine mode) | 8mA to 30A AC or DC |
Resolution | 5 1/2 digit |
Frequency range | 15Hz to 1000Hz |
Frequency accuracy | 0.005% (for 50/60Hz synchronization to mains frequency can be set) |
Frequency resolution | 0.001 Hz bellow 40Hz, 0.01Hz above 40Hz |
Distortion of voltage output | < 0.05% |
Distortion of current output | < 0.1% |
Phase shift range | 0.000° to 359.99° |
Power factor range | -1.000 to +1.000 |
Total electric power range | 0.03VA to 8400VA |
Total electric energy range | 0.03VAs to 2333VAhr |
Time interval range | 1s to 10000s |
Time interval accuracy | 0.01% + 0.1s |
Specifications | ||||||
DC/AC Voltage (sine mode) |
||||||
Range |
% of value |
Max. |
% of value |
Max. |
% of value |
Max. current (mA) |
DC |
DC |
15 - 40Hz |
15 - 40Hz |
40 - 70Hz |
40 - 400Hz |
|
1 - 10V |
0.025 + 0.01 |
100 |
0.03 + 0.02 |
100 |
0.025 + 0.01 |
100 |
10 - 30V |
0.025 + 0.01 |
200 |
0.03 + 0.02 |
200 |
0.025 + 0.01 |
200 |
30 - 70V |
0.025 + 0.01 |
200 |
0.03 + 0.02 |
200 |
0.025 + 0.01 |
300 |
70 - 140V |
0.025 + 0.01 |
200 |
0.03 + 0.02 |
200 |
0.025 + 0.01 |
300 |
140 - 280V |
0.025 + 0.01 |
150 |
0.03 + 0.02 |
150 |
0.025 + 0.01 |
200 |
DC/AC Current (sine mode) |
Range |
% of value |
Max. |
% of value |
% of value |
Max. |
Max. |
DC |
DC |
15 - 40Hz |
40 - 70Hz |
15 - 400Hz |
400 - 1000Hz |
|
8 - 300mA |
0.03 + 0.01 |
8 |
0.04 + 0.02 |
0.03 + 0.01 |
5.5 |
3.5 |
0.3 - 1A |
0.03 + 0.01 |
8 |
0.04 + 0.02 |
0.03 + 0.01 |
5.5 |
3.5 |
1 - 2A |
0.03 + 0.01 |
8 |
0.04 + 0.02 |
0.03 + 0.01 |
5.5 |
3.5 |
2 - 5A |
0.03 + 0.01 |
5 |
0.04 + 0.02 |
0.03 + 0.01 |
3.5 |
3.5 |
5 - 10A |
0.035 + 0.015 |
5 |
0.05 + 0.02 |
0.035 + 0.015 |
3.5 |
3.5 |
10 - 30A |
0.04 + 0.02 |
5 |
0.06 + 0.02 |
0.04 + 0.02 |
3.5 |
3.5 |
Phase, power factor (sine mode) | |
Frequency (Hz) |
Accuracy degrees (°) |
15 - 40Hz |
0.1 |
40 - 70Hz |
0.05 |
70 - 400Hz |
0.1 |
400 - 1000Hz |
0.4 |
Accuracy of power factor: dPF = (1-cos(φ+dφ)/cos(φ) |
AC Power | |||||
Total range: 0.03VA to 8400VA (280kVA with current coil option 140-50) Frequency range: 16Hz to 1000Hz Quantity: W, VA, VAr |
|||||
AC power accuracy (%) for PF = 1.0f = 40 - 70Hz | |||||
Current Range |
Voltage range |
||||
1V - 10V | 10V - 30V | 30V - 70V | 70V - 140V | 140V - 280V | |
30mA –5A | 0,054 | 0,054 | 0,054 | 0,054 | 0,054 |
5 A – 10A | 0,062 | 0,062 | 0,062 | 0,062 | 0,062 |
10A - 30A | 0,070 | 0,070 | 0,070 | 0,070 | 0,070 |
AC electric power accuracy (%) for PF = 0.8f = 40 – 70Hz | |||||
Current Range |
Voltage range |
||||
1V - 10V | 10V - 30V | 30V - 70V | 70V - 140V | 140V - 280V | |
30mA –5A | 0,082 | 0,082 | 0,082 | 0,082 | 0,082 |
5 A – 10A | 0,088 | 0,088 | 0,088 | 0,088 | 0,088 |
10A - 30A | 0,094 | 0,094 | 0,094 | 0,094 | 0,094 |
AC electric power accuracy (%) for PF = 0.5f = 40 – 70Hz | |||||
Current Range |
Voltage range |
||||
1V - 10V | 10V - 30V | 30V - 70V | 70V - 140V | 140V - 280V | |
30mA –5A | 0,082 | 0,082 | 0,082 | 0,082 | 0,082 |
5 A – 10A | 0,088 | 0,088 | 0,088 | 0,088 | 0,088 |
10A - 30A | 0,094 | 0,094 | 0,094 | 0,094 | 0,094 |
Accuracy of power is calculated from value of voltage, current and power factor Active power (W): dP = square root (dU2 + dI2 + dPF2 + 0.012) [%]
|
H/I mode – Harmonic/interharmonic products | |
Fundamental harmonic frequency range | 15Hz to 1000Hz |
Fundamental harmonic amplitude accuracy | 0.2% of range |
Frequency range of harmonic products | 30Hz to 5000Hz (2nd to 50th order) |
Frequency range of inter-harmonic products | 15Hz to 1000Hz |
Max. number of harmonic products | 50 |
Number of inter-harmonic products | 1 |
H/I products amplitude range | max. 30% of RMS fundamental harmonic amplitude |
Amplitude resolution of H/I products | 0.001% |
Noise & Distortion | -60dB |
Output amplitude accuracy | ||
Range |
% of fundamental harmonic amplitude range | % of fundamental harmonic amplitude range |
30Hz to 3000Hz |
3000Hz to 5000Hz |
|
1.0000V to 10.000V |
0.1 |
0.2 |
10.0001 - 30.0000V |
0.1 |
0.2 |
30.001 - 70.000V |
0.1 |
0.2 |
70.001 - 140.000V |
0.1 |
0.2 |
140.001 - 280.000V |
0.1 |
0.2 |
0.0080 - 0.300000A |
0.1 |
0.2 |
0.30001 - 1.00000A |
0.1 |
0.2 |
1.00001 - 2.00000A |
0.1 |
0.2 |
2.00001 - 5.00000A |
0.2 |
0.4 |
5.0001 - 10.0000A |
0.2 |
0.4 |
10.0001 - 30.0000A |
0.4 |
0.8 |
Modulations – Flickers | |
Fundamental harmonic frequency range | 15Hz to 1000Hz |
Single harmonic (2-50) frequency range | 30Hz to 5000Hz |
Modulation frequency range | 0.001Hz to 50Hz |
Modulation depth | 0.000 to 30.000% |
Modulation depth resolution | 0.001% |
RMS amplitude accuracy | 0.2% of range |
Waveform of modulation signal | sine, rectangular |
Duty cycle ration of rectangular modulation signal | 1% to 99% |
Modulation depth accuracy | 0.2% |
Built-in process multimeter | |||
Function |
Range | Accuracy | Resolution |
DC voltage |
0.0000 to +/-12.0000V |
0.01% of value + 0.01% of range |
100uV |
DC current |
0.0000 to 25.0000 mA |
0.01% of value + 0.01% of range |
100nA |
Frequency |
1.00000Hz to 15.0000kHz |
0.005% |
10uHz - 0.1Hz |
Accessories (included) | |
Power cable | 1 pc |
Option 10 Test cable banana-banana 1m 1000V/32A black | 1 pc (3 pcs for three-phase system) |
Option 11 Test cable banana-banana 1m 1000V/32A red | 1 pc (3 pcs for three-phase system) |
Option 12 Test cable banana-banana 1m 1000V/32A blue | 1 pc (3 pcs for three-phase system) |
Option 13 Test cable banana-banana 1m 1000V/32A yellow | 1 pc (3 pcs for three-phase system) |
RS232 cable 1.5m | 1 pc |
Spare fuse | 1 pc |
Interface cable | 2 pcs (for three-phase system) |
Option 133-01 High current adapter | 1 pc |
- Quality Engagement
- Easy change and return
- Delivery Avaliable
- Favorable payment