How do you conduct relay connection point (N.O. / N.C.) tests? How do you test the life cycle of relay’s connection point (N.O. / N.C.)?   How do you evalua

How do you conduct relay connection point (N.O. / N.C.) tests? How do you test the life cycle of relay’s connection
point (N.O. / N.C.)?   How do you evaluate the connection resistance of connection point (N.O. / N.C.) after multiple
tests? How do you evaluate the speed for operating connection point (N.O. / N.C.)? 

Relay, functioning to produce mechanical on-off movement by receiving electric signal to change electro magnet,
is often applied to control other electronic device via receiving electronic signal. Voltage exerted on relay’s coil
allows current to pass through coil and magnetizes core. Armature is then be pulled by core due to electromagnetic
force. Hence, a mechanical on-off movement is produced.  


As shown on the top diagram, PSW 30-108, Relay and PEL-3111 are connected by series. PEL-3111 is set to 80A
current sink. Each time, Relay’s NO-COM is closed, NO-COM is tested for its current reliability. In the meantime,
PSW 80-40.5 is utilized to output sequential power supply to produce control signal to control Relay’s NO-COM.

One GW Instek PSW 80-40.5 can meet the actual measurement requirements via planning Relay’s control signal.
It not only controls signal’s voltage, current, time and period, but also determines the number of operating cycle.
There are totally 20,000 steps and each step can be set from 50ms to 20 days. The number of cycle can reach
1 billion or infinite by different specifications. Relay’s control signal can only verify the mechanical characteristics
of NO-COM and NC-COM. For further electric characteristic verification of NO-COM and NC-COM, PSW 30-108
and PEL-3111 must be concurrently utilized to produce C.C. output. Based upon Relay’s specifications, the combined
application of two instruments can conduct fast current switching test and provide large current verification,
including current withstanding value and current withstanding time so as to ensure Relay’s quality. 

GW instek PEL-3111 Programmable DC Electronic Load (150V, 210A, 1050W)

Related News

How Much Power Can a Rooftop Solar System Still Generate After 5 Years?
09/26/2026 08:44:51

Sau 5 năm vận hành, hệ thống điện mặt trời áp mái có thể vẫn hoạt động ổn định nhưng sản lượng không còn giống thời điểm mới lắp đặt. Mức suy giảm phụ thuộc vào tuổi thọ tấm pin, nhiệt độ, bức xạ, độ ẩm, bụi bẩn, dây dẫn, đầu nối và bộ biến tần.

EMIN is the Official FOTRIC Distributor in Vietnam
09/25/2026 11:55:21

Since August 2020, EMIN has been an official distributor of FOTRIC products and services in Vietnam. FOTRIC specializes in thermal imaging cameras and acoustic imaging cameras for electrical inspection, industrial maintenance, leak detection, research and development, and building inspection.

EMIN is the Official JEIO TECH Distributor in Vietnam
09/25/2026 11:13:01

Since September 2018, EMIN has been an official distributor of JEIO TECH products and services in Vietnam. The company specializes in developing and manufacturing laboratory equipment, environmental testing equipment, and solutions for scientific research and industrial applications.

How Is Cargo Tank Wall Thickness Inspected?
09/25/2026 10:42:16

Non-destructive ultrasonic testing enables tank wall thickness measurements in areas prone to wear, corrosion, or high stress. This method helps assess the service condition of tanks used to transport hazardous materials or waste.

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts