For full functionality of this site it is necessary to enable JavaScript.

SJJW GX50B Reinforcement position tester&Rebar corrosion detection

Integrate the functions of rebar position test , concrete thickness test, rebar diameter test and rebar corrosion degree test into one product.
 
Product usage
Testing concrete cover thickness
Test concrete member internal reinforcement position, rebar spacing, reinforcement position distribution.
Estimation bar diameter
Detection of Cable and Plumbing pipe
Detection of steel corrosion extent
 
Standard Delivery : Main unit, Software, USB connecting
Cable, Instruction manual, Test probe, Probe connecting line, Probe cart
 
Technical Specification : 
1. Specification of Rebar locator : 
Bar diameter application range(mm) : Φ6 – Φ50
Maximum value permissible error of Bar diameter : ≤±1
Protective layer thickness measuring range: 
The first measuring range (mm) : 6 - 90
The second measuring range (mm) : 7-180
The maximum error of reinforced protective layer thickness test value : 
The first measuring range (mm) : 
6 - 59 (≤±1)
60 - 69 (≤±2)
70 -90 ≤±4
The second measuring range (mm) : 
7 - 79 ≤±1
80 - 119 ≤±2
120 - 180 ≤±4
Work temperature ℃ : -10 - +40
Relative humidity RH : < 90%
Power supply mode : Alkaline cell X 6
2. Specification of Rebar corrosion system : 
Measuring Potential : ±2000mV
Test accuracy : ± 1mV
Measuring Space : 1-99 cm (adjustable)
Ambient Temperature : -10℃ ~+40℃
Environment Requirement : to avoid direct exposure, to the sun for a long time.
Relative Humidity : <90%RH
Electromagnetic Interference : no strong alternating electromagnetic field.
Details


  • Quality Engagement
  • Easy change and return
  • Delivery Avaliable
  • Favorable payment

Apply your mail to get promotion information