Tektronix TCP0150 Probe (20MHz, 150A)

Bandwidth DC to ≥20 MHz (-3 dB). Derate with frequency. See Figure 1. (Calculated from Rise Time BW = .35/Rise Time)
Rise time ≤17.5 ns
Max RMS current 150 A
Max peak pulse current 500 A
Minimum sensitivity 5 mA (on oscilloscope 1 mV/div setting)
AC coupling (on oscilloscopes that support AC/DC coupling)

Current ranges 25 A and 150 A
Max bare-wire voltage 600 VRMS CAT I and II
300 VRMS CAT III

Typical characteristics
DC accuracy ±1% typical (3% warranted)
Max amp-second product
25 A range 3,000 aµs150 A range 15,000 aµs
Insertion impedance 0.03 Ω at 1 MHz
0.075 Ω at 5 MHz

.125 at 10 MHz

.3 at 20 MHz

Signal delay ≈ 21 ns
Displayed RMS noise ≤500 μARMS (probe only)
Physical characteristics
Cable length 2 meters (79 in.)
Probe head size
Length 26.8 cm (10.55 in.)Width 4.1 cm (1.6 in.)Height 15.6 cm (6.13 in.)
Max conductor diameter 21 mm x 25 mm (0.83 in. x 1.0 in.)
Shipping weight .7865 kg (1.734 lb.)
Power requirements TCP0150 is powered directly by oscilloscopes with the TekVPI interface
Environmental
Temperature
Operating 0 ºC to +50 ºCNonoperating -40 ºC to +75 ºC
Humidity
Operating 5% to 95% RH (Relative humidity) at up to +30 ºC
5% to 85% RH above 30 ºC up to +50 ºC, noncondensing

Nonoperating 5% to 95% RH (Relative humidity) at up to +30 ºC
5% to 85% RH above 30 ºC up to +75 ºC, noncondensing

Altitude
Operating Up to 2,000 meters (6,560 feet)Nonoperating Up to 12,000 meters (40,000 feet)