4 Common Errors When Testing Devices with an Oscilloscope

2025年10月10日 10時55分24秒

Among the devices used for electronic measurement, the oscilloscope is one of the devices that helps us see directly how the electrical signal is happening. Each waveform displayed on the screen is the “language” of the circuit. Understanding the waveform will help us know whether the circuit is healthy or having problems.

Outstanding advantages of genuine wave machine

Imported oscilloscopes are made from durable, lightweight materials, convenient for moving and operating in lab or field environments. The sharp display shows clear waveforms, helping operators recognize signals in real time. 

In addition, high-end models also integrate large touch screens, bandwidths that can reach hundreds of MHz and flexible scanning speeds. Users can easily adjust measurement parameters directly on the display interface or through reasonably arranged physical buttons. Thanks to that, the results obtained are always highly accurate and stable between measurement channels.

Thanks to its mobility and ability to record diverse signals, oscilloscopes are widely used in many fields such as electronics, automation, communications or technical education.

4 Common Errors When Testing Devices Using an Oscilloscope

Here are four common errors that engineers can quickly detect and fix with an oscilloscope, along with practical tips for measuring.

1. Unstable voltage fluctuations

In many devices, voltage drops or unusual fluctuations often cause the system to operate erratically and intermittently. When observed with an oscilloscope, you will see that the output wave amplitude is constantly changing instead of staying around a central value.

If the amplitude of the oscillation exceeds the allowable threshold, it is likely that the power circuit is weak or the voltage regulator component is no longer responding. If this type of oscillation is identified early, it will help to localize the faulty area much faster than measuring with a conventional meter.

2. Source noise and filter errors are not completely eliminated

An unclean power supply is often the cause of slight distortion or instability of the signal in the post-processing stage. When fed into an oscilloscope, if the DC waveform still has small periodic ripples, it proves that the filter circuit is not capable of eliminating noise. 

The solution is usually to check the filter capacitor and inductor, or increase the capacitor capacity near the load. With control systems, this step is especially important because small noise can cause the microcontroller to reset or cause incorrect control pulses.

3. Loss of oscillation or incorrect frequency

A healthy oscillator circuit must have a stable amplitude and frequency within the allowable range. If the signal appears intermittent or the frequency displayed on the machine deviates significantly from the design, the cause is usually in the oscillator component (crystal, RC, oscillator IC). 

The oscilloscope helps to recognize this condition immediately by comparing the actual wave with the standard wave pattern. The engineer does not need to judge but can directly measure each oscillator stage to determine the component causing the deviation.

4. Distorted or distorted signal

Waveform distortion is a common problem in signal amplification. If the output exhibits clipping, wavefront flattening, or phase shift, the circuit may be operating outside the linear range. In this case, the technician should check the bias points of the transistor, op-amp, or output power.

See more related articles:

See now Tip 6 Oscilloscope Tips for Beginners

Tektronix Launches Tektronix DPO Series 7 Digital Oscilloscope - The New Standard for Performance Measurement Devices

Getting Familiar with Automated Measurements with Waveforms and Signal Generators?

Oscilloscope Group Control Core and How to Use It

Note for you before connecting to the machine

Before connecting the machine, check whether the probe has been compensated correctly. The initial setting mode should be returned to default, select the 1X factor to observe the 1kHz sample signal. After the waveform is stable, start the actual measurement.

Especially for beginners or when you need to compare multiple measurement channels at the same time.

Above are common errors often encountered when testing and analyzing circuits with an oscilloscope that EMIN wants to share with you. Early detection of abnormal waveforms helps engineers handle problems faster, limit widespread damage and save significant repair time.

相关新闻

Reactive Power Compensation Capacitors Bulging or Exploding Before Their Design Lifespan
2026年09月17日 16時10分45秒

The capacitor labels indicated a 10-year lifespan, yet after just two years of service, the casings began to bulge; some even exploded, accompanied by a popping sound and a burnt odor that permeated the electrical room. The maintenance team would install replacements, only for the exact same issue to recur a few months later. This cycle repeated multiple times before anyone finally questioned whether the failures were due to the capacitors reaching the end of their service life or because they were being subjected to conditions beyond their original design specifications.

Overheated Neutral Wire and Neutral Current Exceeding Phase Current: What Are the Causes?
2026年09月17日 15時44分48秒

According to balanced three-phase circuit theory, the neutral current should ideally be zero or negligible compared to the phase current. Yet, technicians frequently discover during inspections at electrical panels that the neutral wire is extremely hot, with measured neutral currents sometimes even exceeding the current in individual phase wires. This is neither a rare occurrence nor a measurement instrument error; rather, it indicates that the system's loads are non-linear, generating harmonics that traditional conductor sizing methods fail to account for