Using a coating thickness gauge helps identify wear on an OPC printer drum rather than relying solely on visual inspection of the surface. The service life of an OPC drum is often considered to have significantly declined when the coating has worn by approximately 5 to 15 μm. When the wear approaches half of the original coating thickness, the drum may be removed from service depending on the remanufacturer’s quality control procedures.