METRIX OX9102 Oscilloscope with Isolated Channels (100 MHz, 2.5 GS/s,5 kHz)
Manufacturer: METRIX Model: OX9102 - Request a Quotation
- Contact
See more: Equipment Calibration-Inspection & Repair Service
Call for the best price
Hanoi city: (024) 35.381.269
Danang city: (023) 63.747.711
Bac Ninh city: (0222) 730.39.68
Hai Phong city: (0225) 730.03.89
HCM city: (028) 38.119.636
Dong Nai: 0345.689.536
HUMAN-MACHINE INTERFACE
Type of display: 7‘’ WVGA colour TFT LCD touch screen, 800x480 – LED backlighting (adjustable standby mode)
Different display mode: 2,500 real acquisition points on screen - Vectors with interpolation
Display of curves on screen: 4 curves + 4 references – Split Screen & Full Screen modes
Screen commands: Touch screen – ANDROID-type icons and graphical commands – customizable channel colours
Choice of language: 15 complete languages, menus & online help
OSCILLOSCOPE MODE
Vertical deflection
Bandwidth: 100 MHz
15 MHz, 1.5 MHz or 5 kHz bandwidth limiter
Number of channels: 2 isolated channels
Input impedance: 1 MΩ ± 0.5% , approx. 12 pF
Maximum input voltage: 600 V / CAT III (1,000V per Probix) – from 50 to 400 Hz – Probix safety connectors
Vertical sensitivity: 16 calibres from 2.5 mV to 200 V/div and up to 156 µV/div in vertical zoom mode (12-bit converter) – Accuracy ± 2%
Vertical zoom "One Click Winzoom" mode (12-bit converter and direct graphical zoom on screen) – x 16 max.
Probe factor (non-Probix) 1 / 10 / 100 / 1,000 or any scaling – definition of measurement unit
Horizontal deflection
Sweep speed 35 calibres from 1 ns/div to 200 s/div., accuracy ± [50 ppm + 500 ps] – Roll mode from 100 ms to 200 s/div
Horizontal zoom "One Click Winzoom" system (direct graphical zoom on screen) x 1 to x 5 or x 100 – storage 100 kpts/channel
Triggering
Mode On all the channels: automatic, triggered, one-shot, auto level 50%
Type Edge, pulse width (16 ns-20 s), delay (48 ns to 20 s), counting (3 to 16,384 events)
Continuous adjustment of Trigger position
Coupling AC, DC GND, HFR, LFR, noise – Level and Hold-Off adjustable from 64 ns to 15 s
Sensitivity ≤ 1.2 division p-p up to 300 MHz
Digital storage
Maximum sampling rate 2.5 GS/s in one-shot mode on each channel (100 GS/s max. in ETS mode)
Vertical resolution 12 bits (vertical resolution 0.025 %)
Memory depth 100 kpts per channel and file viewer in the manager
User storage
File management
Internal = 1 GB to store the files: trace, text, configuration, math functions,
System memory: .pdf print files, .png image files
+ high-capacity removable 2 GB µSD-Card, SDHC 4-32 GB and SDXC > 32 GB
GLITCH mode Duration ≤ 2 ns – 500,000 Min/Max pairs
Display modes Envelope, vector, accumulation-, averaging (factors 2 to 64) – XY (vector) and Y(f)=FFT
Other functions
AUTOSET Complete in under 5 s, with recognition of the channels – Frequency > 30 Hz
FFT analyser & MATH functions 2,500-point FFT (Lin or Log) with measurement cursors – Functions + , - , x , / and mathematical function editor
Cursors 2 or 3 cursors: simultaneous V and T with AUTO measurement: T1, T2, Dt, 1/Dt, dBV, Ph
Automatic measurements Simultaneously with waveform, 20 automatic measurements per channel and on the 4 channels simultaneously with scroll
MULTIMETER MODE
General specifications 2 or 4 channels – 8,000 cts min/max/frequency/relative – TRMS – Time/date-stamped graphical recording in logger mode
AC, DC and AC + DC voltages 600 mV to 600 VRMS, 800 mV to 800 VDC – VDC accuracy +/- (0.5 % + 25 D) – 200 kHz bandwidth
Resistance 80 Ω to 32 MΩ – accuracy 0.5%R+ 25D – Quick continuity test < 10 ms
Other measurements Temperature (HX0035 = KTC, HX0036 = Pt100) / Capacitance 5nF to 5mF / Frequency 200 kHz / Diode test 3.3 V
Single and three-phase power Active, Reactive and Apparent power values plus Power Factor simultaneously with the U & I measurements
HARMONIC ANALYSER MODE
Multi-channel analysis 2 or 4 (depending on model), 63 orders, fundamental frequency 40 to 450 Hz in auto or manual mode
Simultaneous measurements Total Vrms, THD and selected order (% fundamental, phase, frequency, Vrms)
LOGGER MODE
Acquisition Duration: 20,000 s – Interval: 0.2 s – Files: 100,000 measurements
GENERAL SPECIFICATIONS
Configuration memories Not limited according to device - variable file sizes
Printing Network printing via Ethernet/Wifi in .png format
PC communication – software link Ethernet (100 baseT), WiFi-USB (device, 12 Mbs) – "ScopeNet" application software for PC
Software PC: Ethernet and USB, ScopeNet (remote control, data recovery, cursors and automatic measurements)
Android tablet – ScopeAdmin Fleet Administration utility
Mains power supply Li-Ion rechargeable battery (6,900mAH-40 Wh) – Battery life of up to 8 hrs – Adjustable standby mode
Adapter / 2-hour fast charger, universal 98-264 V / 50/60 Hz)
Safety / EMC Safety as per IEC 61010-2-30, 2010 – 600 V CAT III / 1000 V CAT II – EMC as per EN61326-1, 2010
Mechanical specifications 292.5 x 210.6 x 66.2 mm – 2.1 kg with batteries – IP54 protection